Chapter 21 System and Global Settings

SCSI ID Number

When connecting SCSI devices to the VS-1824, the SCSI ID number of each device connected must be set so none of the devices have the same ID number. The VS-1824’s ID number is set to “7” at the factory. When connecting SCSI devices (such as a Zip drive or a CD-R drive) to the VS-1824, be sure to set the SCSI ID number for these devices to a number other than “7.” If no other SCSI ID number is available, it is possible to change the SCSI ID number of the VS-1824.

1.Hold [SHIFT] and press [F5 (SYSTEM)]. The System Menu icon is displayed.

If the System Menu icon does not appear, press [F6 (EXIT)].

2.Press [F2 (GLOBL)].

If “GLOBL” does not appear above [F2], first press [PAGE] until “GLOBL” appears, and then press [F2 (GLOBL)].

3.Use [ ], [ ], [ ], and [ ] to move the cursor to “SCSI Self ID.”

4.Use the TIME/VALUE dial to change the setting for SCSI Self ID.

SCSI Self ID

This sets the VS-1824’s own SCSI ID number (1-7).

The SCSI ID number of the internal CD-RW drive is fixed at “0.”

5.Hold [SHIFT] and press [ZERO]. “STORE OK ?” appears in the display.

6.Press [ENTER/YES]. The current song is saved.

7.Press [PLAY (DISPLAY)] to return to the Playlist display. You must Restart the VS-1824 for the new SCSI ID number to become effective.

IDE Drive Switch

It is possible to use a VS-1824 with just an external hard drive connected to the SCSI port, with turning the internal hard drive OFF. You can turn off the internal hard drive with following procedure.

1.Hold [SHIFT] and press [F5 (SYSTEM)]. The System Menu icon is displayed.

If the System Menu icon does not appear, press [F6 (EXIT)].

2.Press [F2 (GLOBL)].

If “GLOBL” does not appear above [F2], first press [PAGE] until “GLOBL” appears, and then press [F2 (GLOBL)].

3.Use [ ], [ ], [ ], and [ ] to move the cursor to “IDE Drive.”

4.Use the TIME/VALUE dial to change the setting for IDE Drive.

IDE Drive

When not using an internal hard drive, set this to “Off.” The default setting is “On.”

5.Hold [SHIFT] and press [ZERO]. “STORE OK ?” appears in the display.

6.Press [ENTER/YES].

The current song is saved.

7.Press [PLAY (DISPLAY)] to return to the Playlist display. The changed setting becomes effective the next time the VS-1824 is turned on.

254

Page 254
Image 254
Roland VS-1824 owner manual Scsi ID Number, IDE Drive Switch, 254, Scsi Self ID