Recording with Compu Mix

1.Prepare the VS-1824’s initial mixer settings (e.g. panning, faders, EQ, etc.) during song playback. Then press [STOP] and rewind to the beginning of the song.

2.Put the MIDI sequencer into Record mode, and press [PLAY] on the VS-1824.

3.As soon as playback of the VS-1824 starts, immediately hold [SHIFT] and press [SCENE]. The mixer’s initial settings are transmitted from the MIDI OUT connector.

4.As the song continues to play, make adjustments to the faders and other mixer settings as desired.

5.When the song is finished playing, stop the MIDI sequencer and the VS-1824.

This completes recording with Compu Mix. When you rewind to the beginning of the MIDI sequence and the VS-1824 song and then begin playback, all mixer settings are controlled according to the Compu Mix. Save the MIDI song file to a floppy disk or other storage media.

Chapter 22 Specific Applications

Synchronizing with Video Equipment

When used in combination with the optional Roland SI-80S LANC to MTC Converter, you can control the Play and Stop functions of the VS-1824 using consumer video equipment.

This video equipment must provide a consumer video interface that conforms to RCTC time code. On many video products, this interface is labeled “LANC.” Make your connections as shown below, and refer to the SI-80S owner’s manual and the owner’s manual for your video device.

1.

Hold [SHIFT] and press [F5 (SYSTEM)]. The System

 

 

Menu icon appears in the display. If the System Menu

 

 

icon does not appear, press [F6 (EXIT)].

 

2.

Press [F4 (MIDI)]. If “MIDI” does not appear in the

 

 

display above [F4], press [PAGE] until “MIDI” appears,

 

 

and then press [F4 (MIDI)].

 

 

3.

Use [

], [

], [

], and [

] to move the

 

 

cursor and use the TIME/VALUE dial to change the

 

 

setting.

 

 

 

 

 

 

SysEx.Rx (System Exclusive Receive Switch)

 

 

For this application, set this to “On.”

 

 

 

MMC (MIDI Machine Control)

 

 

 

For this application, set this to “SLAVE.”

 

4.

Hold [SHIFT] and press [EXT SYNC]. The Sync/Tempo

 

 

screen appears in the display.

 

 

5.

Use [

], [

], [

], and [

] to move the

 

 

cursor and use the TIME/VALUE dial to change the

 

 

settings.

 

 

 

 

 

 

Sync Error Level

 

 

 

 

 

Normally, this is set to “5.” If you are having difficulties,

 

 

setting a longer interval allows synchronization to

 

 

continue even if there are errors in the source MTC.

 

 

Sync MTC Type

 

 

 

 

 

This selects the MTC frame rate (30, 29N, 29D, 25,24).

 

 

Select the MTC rate so it matches the rate of the SI-80S

 

 

(30, 29D or 29N).

 

 

 

 

6.

 

 

 

 

 

 

Press [PLAY (DISPLAY)] to return to the Playlist display.

Chapter

 

7.

Press [EXT SYNC]. The button indicator lights,

22

 

indicating the VS-1824 is synchronized using MTC

 

 

received from the SI-80S. In this state, commands such as Play and Stop performed on the video equipment are also performed on the VS-1824.