Chapter 21 System and Global Settings

Fan Control

Holding [SHIFT] and pressing the [PREVIOUS] or [NEXT] buttons will have the opposite effect of the Previous/Next Sw setting on this screen. For example, if the Previous/Next Sw is set to “PHRASE,” holding [SHIFT] and pressing [NEXT] will advance you to the next marker.

4.Press [PLAY (DISPLAY)] to return to the Playlist display.

Adjusting the Button Sensitivity

Several buttons on the VS-1824 change functions depending on whether they are pressed once or held down.

STATUS button

 

When pressed:

Changes track status.

When Held Down:

Displays the “Input Assign”

 

screen and shows which inputs

 

or tracks are connected/routed

 

to the track.

[EDIT/SOLO]

 

When pressed:

Displays the Master Block

 

settings.

When Held Down:

Turns on the SOLO function.

[FADER/MUTE]

 

When pressed:

Toggles the physical fader

 

assignments from TR to IN.

When Held Down:

Turns on the MUTE function.

You can specify the length of time the button must be held down in order to use its secondary function.

1.Hold [SHIFT] and press [F5 (SYSTEM)]. The System Menu icon is displayed.

If the System Menu icon does not appear, press [F6 (EXIT)].

2.Press [F2 (GLOBL)].

If “GLOBL” does not appear above [F2], first press [PAGE] until “GLOBL” appears, and then press [F2 (GLOBL)].

3.Use [ ], [ ], [ ], and [ ] to move the cursor to “Switching Time.” Use the TIME/VALUE dial

to change the setting.

Switching Time

This sets the time a button must be held down (0.3-2.0 seconds) in order to use its secondary function.

4.Press [PLAY (DISPLAY)] to return to the Playlist display.

You may find the noise from the VS-1824’s cooling fan to be a concern when recording with a mic nearby. If this is the case, you can program the VS-1824 to turn off the fan during certain operations.

1.Hold [SHIFT] and press [F5 (SYSTEM)]. The System Menu icon is displayed.

If the System Menu icon does not appear, press [F6 (EXIT)].

2.Press [F2 (GLOBL)].

If “GLOBL” does not appear above [F2], first press [PAGE] until “GLOBL” appears, and then press [F2 (GLOBL)].

3.Use [ ], [ ], [ ], and [ ] to move the cursor to “Fan Control.” Use the TIME/VALUE dial to

change the setting.

Fan Control

This specifies which operations cause the cooling fan to turn off.

Off:

The Fan Control feature is disabled. The fan operates constantly.

Play:

The fan stops during playback.

Rec&Play:

The fan stops when Record Standby is enabled, and stays off during recording and playback.

While the cooling fan is stopped for long periods of time, heat can build up and, as a result, may damage the internal hard drive. To avoid this problem, do not leave this set to “Play” or “Rec&Play” for long periods of time. Keep the fan running as much as possible with the Fan Control set to “Off.”

4.Press [PLAY (DISPLAY)] to return to the Playlist display.