S3C84E5/C84E9/P84E9RESET and POWER-DOWN

Table 8-2. S3C84E5/C84E9/P84E9 Set 1, Bank 0 Register Values After RESET

Register Name

Mnemonic

Address

 

 

 

Bit Values After RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dec

Hex

 

7

6

 

5

4

3

2

 

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 0 data register

P0

224

E0H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 1 data register

P1

225

E1H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 2 data register

P2

226

E2H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 3 data register

P3

227

E3H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 4 data register

P4

228

E4H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STOP control register

STPCON

229

E5H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 0 control register (high byte)

P0CONH

230

E6H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 0 control register (low byte)

P0CONL

231

E7H

 

0

0

 

0

0

1

1

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 1 control register (high byte)

P1CONH

232

E8H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 1 control register (low byte)

P1CONL

233

E9H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 2 control register (high byte)

P2CONH

234

EAH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 2 control register (low byte)

P2CONL

235

EBH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 2 interrupt control register

P2INT

236

ECH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 2 interrupt/pending register

P2INTPND

237

EDH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 3 control register (high byte)

P3CONH

238

EEH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 3 control register (low byte)

P3CONL

239

EFH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 4 control register (high byte)

P4CONH

240

F0H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 4 control register (low byte)

P4CONL

241

F1H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 4 interrupt control register

P4INT

242

F2H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 4 interrupt/pending register

P4INTPND

243

F3H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UART pending register

UARTPND

244

F4H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UART data register

UDATA

245

F5H

 

1

1

 

1

1

1

1

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UART control register

UARTCON

246

F6H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/D converter control register

ADCON

247

F7H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/D converter data register(high byte)

ADDATAH

248

F8H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/D converter data register(low byte)

ADDATAL

249

F9H

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watch timer control register

WTCON

250

FAH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oscillator control register

OSCCON

251

FBH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location FCH is factory use only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Basic timer counter register

BTCNT

253

FDH

 

0

0

 

0

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location FEH is not mapped.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interrupt priority register

IPR

255

FFH

 

x

x

 

x

x

x

x

 

x

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-3

Page 221
Image 221
Samsung Converter data registerhigh byte, Converter data registerlow byte, S3C84E5/C84E9/P84E9RESET and POWER-DOWN