2 MENU-SPECIFIC SETTINGS

(when optional interface board is installed)

4. RECORDING AREA SET

The unit’s hard disk is separated into three independent recording areas. Furthermore, five different recording modes can be used for these three areas.

The memory capacity for each area is allocated as a percentage. (Setting units: 1%)

Recording area

Recording mode

Recording method

 

Normal

Manual

Recording is performed in response to manual operation of the operation panel’s

Normal

recording

button.

 

 

 

recording area

Timer recording

Automatic

Recording is performed automatically over the time range set using “7. TIMER SET” from

 

the MAIN MENU.

 

 

 

 

 

 

 

 

 

 

Alarm recording

Automatic

Recording is performed automatically upon occurrence of an alarm set using “9. ALARM

 

REC MODE SET” from the MAIN MENU.

 

Alarm recording

 

 

 

 

 

 

 

 

 

Automatic recording of images before an alarm is performed automatically in

area

Pre-alarm

Automatic

 

recording

accordance with “PRE-ALARM RECORDING” from the MAIN MENU’s “9. ALARM REC

 

 

MODE SET”. This is used as a complementary function for alarm recording.

 

 

 

 

 

 

 

Archive area

Copy

Manual

The required images are copied from another recording area and stored in response to

manual operation of the operation panel’s

button.

 

 

 

 

 

 

 

 

(1) Total capacity display

This section displays the total capacity of the hard disk.

(2) Area-specific capacity display

This section displays the capacity set by the unit for each recording area as a percentage of the total capacity.

zSetting and modification of recording area capacities cannot be carried out from a PC.

(3) Recording area reset

When the overwrite setting is “OFF”, recording will be automatically stopped when the corresponding recording area has been filled with image data. In such a case, [AREA FULL RESET] can be clicked to clear all recorded data and to restart recording from the beginning of each area.

The ability to perform a reset will not be required in the following cases, and for this reason, [AREA FULL RESET] is not displayed.

zWhen the overwrite setting is “ON”.

(1)

(2)

(3)

English

101