2 MENU-SPECIFIC SETTINGS

(when optional interface board is installed)

11. RS-232C/RS-485 SET

This screen displays settings relevant to the unit’s interfaces.

zIt will not be possible to modify settings: The screen displays data for confirmation purposes only.

(1)

(2)

(3)

(4)

(5)

 

Item

Overview

Setting

Description

(1)

CONTROL

Displays the type if interface being

RS-232C

When RS-232C is being used.

used for control of the unit.

RS-485

When RS-485 is being used.

 

 

 

 

 

 

 

(2)

DATA SPEED

Displays the RS-232C or RS-485

2400/4800/9600/

 

communication speed.

19200 (bps)

 

 

 

 

 

 

Displays whether or not status

ON

Status information will be transmitted.

(3)

STATUS INFO

information will be transmitted

 

 

OFF

Status information will not be transmitted.

 

 

during RS-485 communication.

 

 

 

 

 

 

Displays whether or not alarm

ON

Alarm information will be transmitted.

(4)

ALARM INFO

information will be transmitted

 

 

OFF

Alarm information will not be transmitted.

 

 

during RS-485 communication.

 

 

 

 

 

 

 

 

 

(5)

ADDRESS

Displays the address when RS-485

0 to 127

Set within the range of 0 to 127.

has been selected.

 

 

 

 

12. BUZZER SET

Set a warning buzzer to sound for alarms or when the hard disk space reaches zero as described below.

1 Select “ON” or “OFF” for the alarm buzzer.

zTo sound a buzzer on the PC

Create a folder named BUZZER in the PC’s root directory, and save the sound file to use as the buzzer tone as C:\BUZZER\BUZZER.WAV.

When a PC-monitored DVR generates an alarm, the PC also sounds a buzzer, using the saved sound file.

(1)

(2)

(3)

(4)

(5)

(6)

2

 

Item

Default setting

Description

(1)

ALARM

OFF

Sounds a buzzer when an alarm is detected.

(2)

DISK FULL

ON

Sounds a buzzer when the amount of data stored in each of the hard disk’s recording areas has

reached the remaining-space warning level. (JP. 102)

 

 

 

(3)

DISK ERROR

ON

Sounds a buzzer when a hard-disk error occurs.

 

 

 

 

 

LOCK

 

Sounds a buzzer when an operation button not permitted for the current user level is pressed while

(4)

ON

the security lock is set. Specifically, the buzzer sounds twice with an interval of approximately 0.5

WARNING

 

 

 

seconds.

(5)

KEY IN

OFF

The buzzer emits a key-operation sound each time a button is pressed.

 

 

 

 

(6)

NON REC

OFF

Sounds a buzzer when recording is stopped.

2

Click [SAVE].

 

The new settings are saved.

English

109

Page 110
Image 110
Sanyo DSR - 300 manual 109, Buzzer SET, Select on or OFF for the alarm buzzer, To sound a buzzer on the PC