■Replacing the cartridge in the saddle stitch finisher

FINISHER AND SADDLE STITCH FINISHER

Replacing the cartridge in the saddle stitch finisher

Only when the saddle stitch finisher (AR-F16) is installed.

1 Open the lower cover of the saddle stitch finisher.

When an optional inserter is installed, open the front cover of the inserter before opening the lower cover of the finisher.

5 Return the saddle stitch holder and the saddle stitch unit to their respective original positions.

2 Slide out the saddle stitch unit carefully toward the front. 1 Open the lower cover of the saddle stitch finisher.

3 (1) Grasp the grip of the saddle staple holder and pull it out.

(2)While still grasping the grip, rotate the saddle staple holder 90° in the direction of the arrow (rotate to the right).

(2)2 Slide out the saddle stitch unit carefully toward the front.

(1)

4 Remove the empty staple case and set a new one.

Replace both staple cases with new ones. Remove the cover from the staple cartridge and then install the cartridge.

6 Make sure that the finisher is firmly attached to the machine and that A3, A4R, or B4 (11" x 17", 8-1/2" x 11"R, or 8-1/2" x 14") size paper is loaded.

If one of the above paper sizes is not set, test stapling cannot be performed.

7 Close the lower cover of the finisher.

Test stapling is automatically performed on a blank sheet.

This operation is carried out to avoid blank stapling.

NOTE

If test stapling fails to take place, repeat steps 1 to 7.