KEY OPERATOR PROGRAMS
Device settings
These programs are used to disable use of a peripheral unit when it malfunctions or to prohibit use of it temporarily. Also these programs can be used for setting again the functions of peripheral units based on the usage patterns.
In “Device Settings”, the following programs can be set.
●Disable duplex unit
●Disable stapler unit
●Disable paper desk drawers
●Disable finisher
●Disable
●Saddle stitch adjust
Disable duplex unit
This program is used to disable duplex printing when the duplex module malfunctions. If this program is set, only
Disable stapler unit
This program is used to disable stapling when the stapler unit of the finisher or saddle stitch finisher malfunctions.
Disable paper desk drawers
This program is used to disable use of the stand/3 x 500 sheet paper drawer or stand/MPD & 2000 sheet paper drawer when it malfunctions.
Disable finisher
This program is used to disable use of the saddle stitch finisher or finisher when it malfunctions.
Disable mail-bin stacker
This program is used to disable use of the
Saddle stitch adjust
This program is used to adjust the stapling position (folding position) when using the saddle stitch function by installing a saddle stitch finisher.
The value can be adjusted in 0.1 mm increments within ±3.0 mm from the reference position for each paper size.
{Max. +3 mm} {Min.
Print key operator program list
This program is used to print out the list of the key operator programs.
[When using the operation panel with touch panel:]
Key operator programs of the copier feature, facsimile feature, and network scanner feature can be printed.
Key operator code change
This program is used to change the key operator code number (password) from the factory default setting or from the number that has been set.
The key operator must register the key operator code number (password). The key operator code number must be entered to access the key operator programs. Only one key operator code number (password) can be input. For the factory default key operator code number (password), see page xxxx. The key operator must detach the page and store it. Also be sure to remember the registered key operator code number (password).