(OLPLQDWLQJ5HGXQGDQW7UDIILF
122 Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01
Your network system will generate a large number of error messages as
a result of the faulty connection(s). As these messages are taking up
bandwidth, the performance of your network may become very slow.
 &KHFNLQJWKH&DEOH6\VWHP
The occurrence of a problem in the cabling system can be diagnosed with
the remote statistics found on “Remote” tab in the monitor mode of the
RLM Manager.
1. Sel e c t ,QWHUIDFH (WKHUQHW from the pull-down me nu to display the
statistics for the Ethernet interfac e.
2. Compare the number of ,QHUURUV with the number of %ULGJHLQ
SDFNHWV.
When the number of “In errors” is 1% or more of the “Bridge in
packets”, this may indicate a cabling problem.
3. Compare the number of packets 2XWHUURUV with the number of %ULGJH
RXWSDFNHWV.
When the number of “Out errors” is 1% or more of the “Bridge out
packets”, it is likely that there is a cabling problem.
4. Compare the number of 2XWFDUULHUVHQVHHUURUV with the number of
%ULGJHRXWSDFNHWV.
When the number of “Out carrier sense errors” is 1% of the
“Bridge out packets” or the value of the “Out carrier sense errors”
increases too rapidly, this indicates insufficient space on the
network due to a backbone overload, or faulty cabling.