(OLPLQDWLQJ5HGXQGDQW7UDIILF
142 Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01
3. Choose the socket (A or B) for the network interface that you would like
to configure.
4. Click the $GYDQFHG button. The PCCard CP 1515 supports multiple
sub-channels, a pull-down box will appear, allowing you to select a
different operating frequency. The number of channels is subject to local
regulations.
5. In the Wireless Advanced Setup window, use the &KDQQHO pull-down
menu to select a sub-channel that allows for maximum channel
separation from neighboring Access Points RLMs (minimum channel
separation: 25 MHz).
Tabl e 2 lists a number of successful channel combinations that you can
use to configure SIMATIC NET IWL networks with multiple Radio Link
Modules.
•For Dual Channel Configuration (page 138), alternate between
channels A and B.
•For Multiple-Channel Configuration (page 140), alternate between
channels A, B and C
127(
i
The availability of the listed channels in Table 2Recommen ded Sub-
Channel Configurations is subject to local radio regulations that
apply in your country. A complete list of supported channels for your
country can be found in the manual “Industrial Ethernet Wireless
LAN CP Basics” and via the MOBIC web site
KWWSZZZVLHPHQVFRPPRELF.