'RLQJD)RUFHG5HORDG
Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01 249
& 6WHS6HWWRo)RUFHG5HORDGp0RGH
1. Remove the cover of the RLM.
2. Locate the two small holes on the long-edge side of the processor
module, marked “Reset” and “Reload” (see Figure44).
)LJXUH 5HVHWDQG5HORDG%XWWRQV
3. Use a small pointed object, such as the tip of a ball-point, to press the
5HVHW button.
4. Release the 5HVHW button and wait 5 seconds.
The Radio Link Module will do start-up diagnostics, characterized by LED
activity, where the LEDs will change color in the range Amber, Red and
Green.