6HFXULQJ$FFHVVWR:LUHOHVV'DWD
166 Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01
5$',866HUYHU$FFHVV&RQWURORADIUS Access Control enables you to:
• Specify the lifetime of a granted authorization
• Set the authorization password
• Assign up to two RADIUS servers for validating the MAC address of
wireless stations.
For each RADIUS server you will need to specify:
• The unique IP address of the RADIUS server
• The Authentication port as used by the selected server.
To restrict access to your network using MAC address control via a RADIUS
server:
1. Start the RLM Manager and select the Acess Point RLM.
2. Click the (GLW button.
3. Select the $FFHVV&RQWURO tab.
4. Click the lower (GLW button to display the RADIUS server name and
secret parameter.
5. Enable the check box (QDEOH5$',866HUYHU.
• Default value is: RADIUS Access Control Disabled
For more information refer the help-file (press ) of the RLM Manager.
F1