© Siemens AG 2007

 

 

 

Communication

 

 

 

 

 

Industrial Ethernet

 

 

 

 

SCALANCE X Industrial Ethernet switches

 

 

 

 

 

 

 

Type

SCALANCE X414-3E

SCALANCE X408-2

 

 

 

Network size parameters / TP cable length

 

 

 

 

 

 

• 0 to 55 m

IE TP Torsion Cable with IE FC RJ45 Plug

IE TP Torsion Cable with IE FC RJ45 Plug

 

 

 

• 0 to 85 m

IE FC Marine/ Trailing/ Flexible/ FRNC Cable

IE FC Marine/ Trailing/ Flexible/ FRNC Cable with

 

 

 

 

with IE FC RJ45 Plug

IE FC RJ45 Plug

 

 

 

• 0 to 100 m

IE FC Standard Cable GP with IE FC RJ45

IE FC Standard Cable GP with IE FC RJ45 Plug

 

 

 

 

Plug

 

 

 

 

• 0 to 750 m

Cable length multimode FOC at 1000 Mbit/s;

Cable length multimode FOC at 1000 Mbit/s;

 

 

 

 

MM492-2 with glass FOC

MM492-2 with glass FOC

 

 

 

 

50/125 m;

50/125 m;

 

 

 

 

2.7 dB/km with 850 nm;

2.7 dB/km with 850 nm;

 

 

 

 

600 MHz x km

600 MHz x km

 

 

 

• 0 to 3000 m

Cable length multimode FOC at 100 Mbit/s;

Cable length multimode FOC at 100 Mbit/s;

 

 

 

 

MM491-2 with glass FOC

MM491-2 with glass FOC

 

 

 

 

62.5/125 m or 50/125 m;

62.5/125 m or 50/125 m;

 

 

 

 

1 dB/km with 1300 nm;

1 dB/km with 1300 nm;

 

 

 

 

600 MHz x km

600 MHz x km

 

 

 

• 0 to 10 km

Cable length singlemode FOC at 1000 Mbit/s;

Cable length singlemode FOC at 1000 Mbit/s;

 

 

 

 

MM492-2LD with glass FOC

MM492-2LD with glass FOC

 

 

 

 

10/125 m or 9/125 m;

10/125 m or 9/125 m;

 

 

 

 

0.5 dB/km with 1300 nm

0.5 dB/km with 1300 nm

 

 

 

• 0 to 26 km

Cable length singlemode FOC at 100 Mbit/s;

Cable length singlemode FOC at 100 Mbit/s;

 

 

 

 

MM491-2LD with glass FOC 10/125 m or

MM491-2LD with glass FOC 10/125 m or

 

 

 

 

9/125 m;

9/125 m;

 

 

 

 

0.5 dB/km with 1300 nm

0.5 dB/km with 1300 nm

 

 

 

• 0 to 40 km

Cable length singlemode FOC at 1000 Mbit/s;

Cable length singlemode FOC at 1000 Mbit/s;

 

 

 

 

MM492-2LH with glass FOC

MM492-2LH with glass FOC

 

 

 

 

10/125 m or 9/125 m;

10/125 m or 9/125 m;

 

 

 

 

0.5 dB/km with 1300 nm

0.5 dB/km with 1300 nm

 

 

 

• 0 to 70 km

Cable length singlemode FOC at 1000 Mbit/s;

Cable length singlemode FOC at 1000 Mbit/s;

 

 

 

 

MM492-2LH+ with glass FOC

MM492-2LH+ with glass FOC

 

 

 

 

10/125 m or 9/125 m;

10/125 m or 9/125 m;

 

 

9

 

0.5 dB/km with 1300 nm

0.5 dB/km with 1300 nm

 

 

 

 

 

 

Permissible ambient conditions

 

 

 

 

 

 

• Operating temperature

0 to +60 °C

0 to +60 °C

 

 

 

 

 

• Transport/storage temperature

-40 °C to +80 °C

-40 °C to +80 °C

 

 

 

• Relative humidity during operation

< 95% (no condensation)

< 95% (no condensation)

 

 

 

Design

 

 

 

 

 

 

• Dimensions (W x H x D) in mm

344 x 145 x 117

275 x 145 x 117

 

 

 

• Weight

3.1 kg

1.9 kg

 

 

 

• Mounting

S7-300 rail, DIN rail

S7-300 rail, DIN rail

 

 

 

Degree of protection

IP20

IP20

 

 

 

Approvals

 

 

 

 

 

 

• Radio interference suppression level

EN 61000-6-4 Class A

EN 61000-6-4 Class A

 

 

 

 

 

 

 

 

• Noise immunity

EN 61000-6-2

EN 61000-6-2

 

 

 

 

 

 

 

 

cUL-Listung

UL 60950-1, CSA C22.2 No. 60950-1,

UL 60950-1, CSA C22.2 No. 60950-1,

 

 

 

UL 508, CSA C22.2 No. 14-M91

UL 508, CSA C22.2 No. 14-M91

 

 

 

UL 1604 and 2279 (Hazardous Location)

UL 1604 and 2279 (Hazardous Location)

 

 

 

 

 

 

 

 

• FM

FM 3611,

FM 3611,

 

 

 

FM Hazardous Location

FM Hazardous Location

 

 

 

 

 

 

 

 

• ATEX Zone 2

EN 50021

EN 50021

 

 

 

 

 

 

 

 

C-Tick

AS/NZS 2064 (Class A)

AS/NZS 2064 (Class A)

 

 

 

 

 

 

 

 

• CE

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

 

 

 

 

 

 

 

 

• Shipbuilding approvals

• Germanischer Lloyd (GL)

Available soon

 

 

 

• American Bureau of Shipping (ABS)

 

 

 

 

 

• Llyods Register of Shipping (LRS)

 

 

 

 

• Bureau Veritas (BV)

• Nippon Kaiji Kyokai (NK)

• Det Norske Veritas (DNV)

Siemens ST PCS 7 · November 2007

9/13

Page 141
Image 141
Siemens ST PCS 7 manual Network size parameters / TP cable length, Permissible ambient conditions, Design