Siemens ST PCS 7 manual Microbox automation system, 10/4

Models: ST PCS 7

1 344
Download 344 pages 20.13 Kb
Page 184
Image 184

© Siemens AG 2008

Automation systems

Microbox automation system

Overview

 

Design

SIMATIC PCS 7 AS RTX

With consideration of the scalable automation performance, the SIMATIC PCS 7 AS RTX Microbox automation system represents the starter system in the bottom performance range of SIMATIC PCS 7.

The compact and rugged design as well as the complete ab- sence of fans and rotating storage media mean that it resistant to vibration and shock, and make it highly suitable for mainte- nance-free 24-hour continuous operation at ambient tempera- tures up to 55 °C. Particularly with small applications, it is an ex- ceptionally good alternative to standard automation systems of S7-400 design.

Application

As a result of its exceptional physical properties and small di-

10 mensions, the SIMATIC PCS 7 AS RTX Microbox automation sys- tem is exceptionally suitable for industrial use at plant level. Just like the runtime systems (AS plus OS) and complete systems (AS plus OS and ES) based on SIMATIC PCS 7 BOX, it can be used for:

Small production applications

Package units

Laboratory automation

SIMATIC PCS 7 AS RTX can also be combined with SIMATIC PCS 7 BOX or automation systems of S7-400 design within a plant.

 

 

2 x Gigabit

PROFIBUS

Cooling slots

4 x USB 2.0

Ethernet

12 Mbit/s

24 V DC

DVI-I connection

COM1

power supply

(DVI/VGA combined)

 

All-metal enclosure

 

 

Displays:

Interface inscriptions

Power

 

Watchdog

 

Design of the SIMATIC PCS 7 AS RTX

The SIMATIC PCS 7 AS RTX Microbox automation system is based on a SIMATIC Microbox PC 427B with a system-specific configuration. The following are preinstalled on the supplied

2-GB CompactFlash card:

Windows XP Embedded operating system

WinAC RTX controller software

SIMATIC PC DiagMonitor diagnostics software

Microbox automation system with CompactFlash card

The SIMATIC PCS 7 AS RTX has an integral power supply with electrical isolation and mains buffering. Process data can be safely saved by a buffered 2-MB SRAM.

Parameterizable monitoring functions (program execution/ watchdog, processor and board temperatures) as well as en- hanced diagnostics/messages (e.g. operating hours counter, hard disk/system status) can be recorded via SIMATIC PC DiagMonitor and the maintenance station (PCS 7 asset manage- ment), and evaluated or signaled by LED (power/watchdog).

10/4

Siemens ST PCS 7 · Update November 2008

Page 184
Image 184
Siemens ST PCS 7 manual Microbox automation system, 10/4