Siemens ST PCS 7 manual 11/35, Digital electronics modules, DI Namur

Models: ST PCS 7

1 344
Download 344 pages 20.13 Kb
Page 249
Image 249

© Siemens AG 2007

 

 

 

 

 

 

 

 

Process I/O

 

 

 

 

 

 

 

 

 

 

 

ET 200iSP distributed I/O

 

 

 

 

 

 

 

Electronics modules and watchdog module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection and Ordering Data

Order No.

 

Selection and Ordering Data

Order No.

 

 

 

 

 

 

Digital electronics modules

 

 

 

 

Digital output module with

 

 

 

 

 

 

 

 

Digital input modules

 

 

 

 

L switch-off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(external actuator switch-off via

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 DI NAMUR

6ES7 131-7RF00-0AB0

B)

 

 

L-signal);

 

 

 

 

 

 

 

 

For evaluation of NAMUR sen-

 

 

 

 

for switching of solenoid valves,

 

 

 

 

 

 

 

 

sors, connected/non-connected

 

 

 

 

DC relays, signal lamps, actua-

 

 

 

 

 

 

 

 

contacts, as well as for recording

 

 

 

 

tors

 

 

 

 

 

 

 

 

counter pulses or measuring fre-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 DO DC 23.1 V/20 mA

6ES7 132-7GD00-0AB0

 

B)

 

 

 

 

 

quencies

 

 

 

 

 

 

 

 

 

 

 

 

• 4 channels with 20 mA each

 

 

 

 

 

 

 

 

• 8 x NAMUR (NAMUR sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

 

 

 

on/off, NAMUR changeover

 

 

 

 

 

 

 

 

 

 

 

 

contact) or connected/

 

 

 

 

• Wire break monitoring

 

 

 

 

 

 

 

 

non-connected inputs

 

 

 

 

• Parameterizable connection of

 

 

 

 

 

 

 

 

(single/changeover contact)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

substitute value in case of CPU

 

 

 

 

 

 

 

 

• 2 channels optionally usable as

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

counters (max. 5 kHz) or fre-

 

 

 

 

Load-free switching of outputs

 

 

 

 

 

 

 

 

quency meters (1 Hz ... 5 kHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

via external intrinsically-safe

 

 

 

 

 

 

 

 

• Time tagging 5 ms, rising or fall-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

signal

 

 

 

 

 

 

 

 

ing edge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 DO DC 17.4 V/27 mA

6ES7 132-7GD10-0AB0

 

 

 

 

 

 

 

• Wire break monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• 4 channels with 27 mA each or

 

 

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• 2 outputs connected in parallel

 

 

 

 

 

 

 

 

• Sensor power supply monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with 54 mA each

 

 

 

 

 

 

 

 

• Flutter monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

 

 

 

Digital output module with

 

 

 

 

• Wire break monitoring

 

 

 

 

 

 

 

 

H switch-off

 

 

 

 

• Parameterizable connection of

 

 

 

 

 

 

 

 

(external actuator switch-off via

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

substitute value in case of CPU

 

 

 

 

 

 

 

 

H-signal);

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

for switching of solenoid valves,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Load-free switching of outputs

 

 

 

 

 

 

 

 

DC relays, signal lamps, actua-

 

 

 

 

 

 

 

 

 

 

 

 

tors

 

 

 

 

via external intrinsically-safe sig-

 

 

 

 

 

 

 

 

 

 

 

 

 

nal

 

 

 

 

 

 

 

 

4 DO DC 23.1 V/20 mA

6ES7 132-7RD01-0AB0

B)

 

 

 

 

 

 

 

 

 

 

 

 

4 DO DC 17.4 V/40 mA

6ES7 132-7GD20-0AB0

 

 

 

 

 

 

 

• 4 channels with 20 mA each

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• 4 channels with 40 mA each or

 

 

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• 2 outputs connected in parallel

 

 

 

 

 

 

 

 

• Wire break monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with 80 mA each

 

 

 

 

 

 

 

 

• Parameterizable connection of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

 

 

 

substitute value in case of CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Wire break monitoring

 

 

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

 

 

 

Load-free switching of outputs

 

 

 

 

• Parameterizable connection of

 

 

 

 

 

 

 

 

via external intrinsically-safe

 

 

 

 

substitute value in case of CPU

 

 

 

 

 

 

 

 

signal

 

 

 

 

failure

 

 

 

 

 

 

 

 

4 DO DC 17.4 V/27 mA

6ES7 132-7RD11-0AB0

 

 

 

Load-free switching of outputs

 

 

 

 

 

 

 

 

• 4 channels with 27 mA each or

 

 

 

 

via external intrinsically-safe sig-

 

 

 

 

 

11

 

 

 

 

 

 

nal

 

 

 

 

 

 

• 2 outputs connected in parallel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B) Subject to export regulations: AL: N, ECCN: EAR99H

 

 

 

 

 

 

with 54 mA each

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

• Wire break monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

• Parameterizable connection of

 

 

 

 

 

 

 

 

 

 

 

 

 

substitute value in case of CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

 

 

 

 

Load-free switching of outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

via external intrinsically-safe sig-

 

 

 

 

 

 

 

 

 

 

 

 

 

nal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 DO DC 17.4 V/40 mA

6ES7 132-7RD21-0AB0

 

 

 

 

 

 

 

 

 

 

 

 

• 4 channels with 40 mA each or

 

 

 

 

 

 

 

 

 

 

 

• 2 outputs connected in parallel with 80 mA each

Short-circuit monitoring

• Wire break monitoring

• Parameterizable connection of substitute value in case of CPU failure

Load-free switching of outputs via external intrinsically-safe sig- nal

Siemens ST PCS 7 · November 2007

11/35