© Siemens AG 2007

Process I/O

ET 200S distributed I/O

Digital electronics modules

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection and Ordering Data

Order No.

 

Selection and Ordering Data

Order No.

 

 

 

Digital inputs for floating contacts

 

 

 

 

DO 2 x 24 V DC/2 A, High Fea-

 

6ES7 132-4BB31-0AB0

 

B)

 

 

 

 

 

 

 

 

ture, with diagnostics

 

 

 

 

 

 

DI 2 x 24 V DC, standard

 

6ES7 131-4BB01-0AA0

B)

 

 

 

 

 

 

 

 

• Connection of a default value by

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

channel in the event of CPU fail-

 

 

 

 

 

 

DI 4 x 24 V DC, standard

 

6ES7 131-4BD01-0AA0

B)

 

 

ure (parameterizable)

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

Short-circuit monitoring by

 

 

 

 

 

 

 

 

 

 

 

 

channel

 

 

 

 

 

 

DI 2 x 24 V DC, High Feature;

 

6ES7 131-4BB01-0AB0

B)

 

 

 

 

 

 

 

 

• Broken wire monitoring by chan-

 

 

 

 

 

 

with diagnostics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

nel (when "1" signal)

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO 4 x 24 V DC/0.5 A, standard

 

6ES7 132-4BD01-0AA0

 

 

 

 

DI 4 x 24 V DC, High Feature;

 

6ES7 131-4BD01-0AB0

 

 

 

 

 

 

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

with diagnostics

 

 

 

 

 

 

 

 

 

 

 

Short-circuit monitoring

 

 

 

 

 

DO 4 x 24 V DC/2 A, standard

 

6ES7 132-4BD32-0AA0

 

B)

 

 

Ordering unit 5 items

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

DI 4 x 24 to 48 V AC/DC, High

 

6ES7 131-4CD00-0AB0

B)

 

 

Digital output for AC voltage (suitable for solenoid valves,

 

 

 

Feature; with diagnostics

 

 

 

 

 

AC contactors, indicator lights etc.)

 

 

 

 

 

• Wire break monitoring (external

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO 2 x 24 to 230 V AC, 2 A

 

6ES7 132-4FB01-0AB0

 

B)

 

 

resistance circuit required)

 

 

 

 

 

• Connection of a default value by

 

 

 

 

 

 

• Monitoring of the fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

channel in the event of CPU fail-

 

 

 

 

 

 

• Monitoring of the load voltage

 

 

 

 

 

ure (parameterizable)

 

 

 

 

 

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay output (suitable for solenoid valves, contactors, motor

 

 

 

DI 4 x 24 V DC, NAMUR

 

6ES7 131-4RD00-0AB0

B)

 

 

 

 

 

 

starters, miniature motors and indicator lights)

 

 

 

Ordering unit 1 item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 x RO, NO contact

 

6ES7 132-4HB01-0AB0

 

 

 

 

DI 2 x 120 V AC, standard

 

6ES7 131-4EB00-0AB0

B)

 

 

24 to 120 V DC/5 A

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

24 to 230 V AC/5 A

 

 

 

 

 

 

DI 2 x 230 V AC, standard

 

6ES7 131-4FB00-0AB0

B)

 

 

• Connection of a default value by

 

 

 

 

 

 

 

 

 

channel in the event of CPU fail-

 

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ure (parameterizable)

 

 

 

 

 

 

Failsafe digital input

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

4/8 F-DI 24 V DC PROFIsafe

 

6ES7 138-4FA03-0AB0

B)

 

 

2 x RO, changeover contact

 

6ES7 132-4HB10-0AB0

 

B)

 

 

8 DI safety-related SIL 2 or 4 DI

 

 

 

 

 

24 to 48 V DC/5 A

 

 

 

 

 

 

safety-related SIL 3, with diagnos-

 

 

 

 

 

24 to 230 V AC/5 A

 

 

 

 

 

 

tics

 

 

 

 

 

• Connection of a default value by

 

 

 

 

 

 

• Cyclic short-circuit test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

channel in the event of CPU fail-

 

 

 

 

 

 

• Discrepancy monitoring of

 

 

 

 

 

ure (parameterizable)

 

 

 

 

 

 

2 channels for SIL 3 (adjustable

 

 

 

 

 

Ordering unit 5 items

 

 

 

 

 

 

discrepancy time)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failsafe digital output

 

 

 

 

 

• Safe monitoring of communica-

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

4 F-DO 24 V DC/2 A PROFIsafe

6ES7 138-4FB02-0AB0

B)

 

tion with PROFIsafe

 

 

 

 

 

 

 

Ordering unit 1 item

 

 

 

 

 

Safety-related up to SIL 3, with

 

 

 

 

 

 

 

 

 

 

diagnostics, switching to low/high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital outputs for DC voltage (suitable for solenoid valves, DC contactors, indicator lights etc.)

DO 2 x 24 V DC/0.5 A, standard

6ES7 132-4BB01-0AA0

B)

Ordering unit 5 items

 

 

 

 

 

DO 2 x 24 V DC/2 A, standard

6ES7 132-4BB31-0AA0

 

Ordering unit 5 items

 

 

 

 

 

DO 2 x 24 V DC/0.5 A, High

6ES7 132-4BB01-0AB0

B)

Feature, with diagnostics

 

 

Connection of a default value by channel in the event of CPU fail- ure (parameterizable)

Short-circuit monitoring by channel

Broken wire monitoring by chan- nel (when "1" signal)

Ordering unit 5 items

Short-circuit monitoring by channel

Overload monitoring by channel

Broken wire monitoring by chan- nel (when "1" signal)

Safe monitoring of communica- tion with PROFIsafe

Diagnostics inside module Ordering unit 1 item

Accessories

 

 

Reserve modules for ET 200S

 

 

for reserving unused slots for any

 

 

electronics module

 

 

• 15 mm wide (Ordering unit

6ES7 138-4AA01-0AA0

B)

5 items)

 

 

• 30 mm wide (Ordering unit

6ES7 138-4AA11-0AA0

B)

1 item)

 

 

For further accessories, e.g. for

 

 

 

 

labeling, see Catalog IK PI

 

 

 

 

 

B) Subject to export regulations: AL: N, ECCN: EAR99H

11/46

Siemens ST PCS 7 · November 2007

Page 260
Image 260
Siemens ST PCS 7 manual 11/46