© Siemens AG 2008

Automation systems

Fault-tolerant automation systems

Selection and ordering data

Order No.

AS 414-4-2H (Redundant Station)

6ES7 656-

with SIMATIC PCS 7 AS Runtime license for

 

 

 

 

 

-

 

 

B

 

7

7

7

7

7

7

7

7

100 POs

 

 

 

 

 

 

 

 

 

 

2 x CPU with 2 interfaces (MPI/DP master and

 

 

 

 

 

 

 

 

 

 

DP master)

 

 

 

 

 

 

 

 

 

 

2 x 2.8 MB RAM (1.4 MB each for program and

 

 

 

 

 

 

 

 

 

 

data)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of delivery

 

 

 

 

 

 

 

 

 

 

• Preassembled and tested

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory card

 

 

 

 

 

 

 

 

 

 

• 2 x memory card 2 MB RAM (up to approx.

 

B

 

 

 

 

 

 

 

 

180 POs)

 

 

 

 

 

 

 

 

 

 

• 2 x memory card 4 MB RAM (up to approx.

 

C

 

 

 

 

 

 

 

 

300 POs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU type

 

 

 

 

 

 

 

 

 

 

• 2 x CPU 414-4H (up to approx. 250 POs)

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sync modules and cables

 

 

 

 

 

 

 

 

 

 

• 2 x 2 sync modules for distances up to 10 m

3

 

 

 

 

 

 

and

 

 

 

 

 

 

 

 

 

 

2 x FO sync cable, 1 m

 

 

 

 

 

 

 

 

 

 

• 2 x 2 sync modules for up to 10 km and

4

 

 

 

 

 

 

2 x FO sync cable, 1 m, for testing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interface module to

 

 

 

 

 

 

 

 

 

 

Industrial Ethernet plant bus1)

 

 

 

 

 

 

 

 

 

 

• 2 x CP 443-1 for redundant interface module1)

1

 

 

 

 

 

• 2 x 2 CP 443-1 for 4-way connection1)

2

 

 

 

 

 

Rack

 

 

 

 

 

 

 

 

 

 

• 1 x UR2-H (2 x 9 slots), aluminum

1

 

 

 

• 1 x UR2-H (2 x 9 slots), steel

2

 

 

 

• 2 x UR2 (9 slots), aluminum

3

 

 

 

• 2 x UR2 (9 slots), steel

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply (without backup batteries)

• 2 x PS 407, 10 A for 120/230 V AC/DC

B

• 2 x PS 407, 10 A for 120/230 V AC/DC, redun-

C

dant design

 

• 2 x PS 407, 20 A for 120/230 V AC/DC

D

• 2 x 2 PS 407, 10 A for 120/230 V AC/DC, re-

E

dundant design

 

• 2 x PS 405, 10 A for 24 V DC

G

• 2 x PS 405, 10 A for 24 V DC, redundant de-

H

sign

 

• 2 x PS 405, 20 A for 24 V DC

J

• 2 x PS 405, 10 A for 24 V DC, redundant de-

K

sign

Additive PROFIBUS DP interface modules1)

• Without CP 443-5 Extended

0

• 2 x CP 443-5 Extended

1

• 2 x 2 CP 443-5 Extended1)

2

• 2 x 3 CP 443-5 Extended1)

3

• 2 x 4 CP 443-5 Extended1)

4

1)Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply.

Selection and ordering data

Order No.

AS 417-4-2H (Redundant Station)

6ES7 656-

 

 

with SIMATIC PCS 7 AS Runtime license for

7 7 7 7 7 -

7 7 B 7

 

100 POs

 

 

 

 

2 x CPU with 2 interfaces (MPI/DP master and

 

 

 

DP master)

 

 

 

2 x 30 MB RAM (15 MB each for program and

 

 

 

data)

 

 

 

Type of delivery

 

 

 

• Preassembled and tested

8

 

 

Memory card

 

 

 

• 2 x memory card 4 MB RAM (up to approx.

C

 

 

300 POs)

 

 

 

• 2 x memory card 8 MB RAM (up to approx.

D

 

 

800 POs)

 

 

 

• 2 x memory card 16 MB RAM (up to approx.

E

 

 

3,000 POs)

 

 

 

CPU type

 

 

 

• 2 x CPU 417-4H (up to approx. 2,500 POs)

M

 

 

Sync modules and cables

 

 

 

• 2 x 2 sync modules for distances up to 10 m

3

 

 

and

 

 

 

2 x FO sync cable, 1 m

 

 

 

• 2 x 2 sync modules for up to 10 km and

4

 

 

2 x FO sync cable, 1 m, for testing

 

 

 

Interface module to

 

 

 

Industrial Ethernet plant bus1)

 

 

 

• 2 x CP 443-1 for redundant interface module1)

1

 

 

• 2 x 2 CP 443-1 for 4-way connection1)

2

 

 

Rack

 

 

 

• 1 x UR2-H (2 x 9 slots), aluminum

 

1

 

• 1 x UR2-H (2 x 9 slots), steel

 

2

10

• 2 x UR2 (9 slots), aluminum

 

3

 

 

• 2 x UR2 (9 slots), steel

 

4

 

Power supply (without backup batteries)

 

 

 

• 2 x PS 407, 10 A for 120/230 V AC/DC

 

B

 

• 2 x PS 407, 10 A for 120/230 V AC/DC, redun-

 

C

 

dant design

 

 

 

• 2 x PS 407, 20 A for 120/230 V AC/DC

 

D

 

• 2 x 2 PS 407, 10 A for 120/230 V AC/DC, re-

 

E

 

dundant design

 

 

 

• 2 x PS 405, 10 A for 24 V DC

 

G

 

• 2 x PS 405, 10 A for 24 V DC, redundant de-

 

H

 

sign

 

 

 

• 2 x PS 405, 20 A for 24 V DC

 

J

 

• 2 x PS 405, 10 A for 24 V DC, redundant de-

 

K

 

sign

 

 

 

Additive PROFIBUS DP interface modules1)

• Without CP 443-5 Extended

0

• 2 x CP 443-5 Extended

1

• 2 x 2 CP 443-5 Extended1)

2

• 2 x 3 CP 443-5 Extended1)

3

• 2 x 4 CP 443-5 Extended1)

4

1)Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply.

Siemens ST PCS 7 · Update November 2008

10/19

Page 199
Image 199
Siemens ST PCS 7 manual 10/19, AS 414-4-2H Redundant Station 6ES7