Communication

PROFIBUS PA

Routers: DP/PA link and DP/PA coupler

Technical specifications

DP/PA coupler

Connection for PROFIBUS PA

• DP/PA coupler Ex [i]

2 terminals of a 4-pole screw-type

 

terminal, integral terminating

 

resistor

• DP/PA coupler FDC 157-0

4-pole screw-type terminal for

 

connection and looping through,

 

selectable terminating resistor

IM 153-2 High Feature (for extended temperature range)

Function

Linking of PROFIBUS DP

 

(9.6 kbit/s to 12 Mbit/s, slave

 

functionality) and PROFIBUS PA

 

with support of the "Configuration

 

in Run" function

 

The DP/PA link function is only

 

implemented by extending the

 

IM 153-2 High Feature with one or

 

more DP/PA couplers. Stand-

Connection for PROFIBUS DP

Backplane bus

Diagnostic displays

DP/PA coupler Ex [i] and DP/PA coupler FDC 157-0

Additive with DP/PA coupler FDC 157-0

Power supply

Current consumption

DP/PA coupler Ex [i]

DP/PA coupler FDC 157-0 Voltage at coupler output

DP/PA coupler Ex [i]

DP/PA coupler FDC 157-0 Max. current at coupler output

DP/PA coupler Ex [i]

DP/PA coupler FDC 157-0

Power loss

DP/PA coupler Ex [i]

DP/PA coupler FDC 157-0 Operating temperature

DP/PA coupler Ex [i] and DP/PA coupler FDC 157-0

Dimensions (W x H x D) in mm Weight

9-pin Sub-D plug,

contact assignment as described in IEC 61158/EN 50170

Connection through S7 back- plane bus connector (only neces- sary for DP/PA link); non-floating

The active BM DP/PA bus mod- ules are required for the hot swapping function

Bus activity "DP" (yellow) Bus activity "PA" (yellow)

24 V DC "ON" (green)

Group fault "SF" (red) Bus fault "BF" (rot)

DP/PA coupler activated, feed- ing/transmitting "ACT" (yellow), only with PA redundancy

24 V DC (20.4 V ... 28.8 V)

Max. 400 mA

Max. 2300 mA

13 V ... 14 V DC

31 ± 1 V DC

110 mA

1 A (up to 50 °C), 0.8 A (up to 60 °C)

Approx. 7 W

Approx. 13.4 W

-25 ... +60 °C (horizontal installation)

-25 ... +40 °C (vertical installation) 80 x 125 x 130

Approx. 515 g

 

alone operation of the IM 153-2

 

 

High Feature is not possible.

 

 

1 Y coupler, up to

 

 

5 DP/PA couplers or up to

 

 

64 slaves can be connected

 

 

Isolation from the higher-level DP

 

 

master system

 

Interfaces

 

 

• Connection for PROFIBUS DP

9-pin Sub-D plug, contact assign-

 

 

ment as described in

 

 

IEC 61158/EN 50170, Vol. 2

 

• Backplane bus

Connection through S7 back-

 

 

plane bus connector, non-floating

 

 

Bus modules and profile rails for

 

 

hot swapping are required for the

 

 

hot swapping function and for a

 

 

redundant PROFIBUS DP inter-

 

 

face module.

 

Diagnostic displays

Group fault "SF" (red)

 

 

Bus fault DP "BF 1" (red)

 

 

Bus fault PA "BF 2" (red)

 

 

IM active "ACT" (yellow)

9

 

24 V DC "ON" (green)

Power supply

24 V DC

 

Current consumption

Max. 100 mA (in DP/PA link)

 

 

Max. 200 mA (in Y-link)

 

Power loss

Approx. 2 W (in DP/PA link)

 

 

Approx. 4 W (in Y-link)

 

Voltage failure bridging

20 ms

 

Mechanical design of power

4-pin screw terminal, short-

 

supply

circuiting link between PE and

 

 

M24; the short-circuiting link must

 

 

be removed for floating operation

 

 

(independent of this, the DP inter-

 

 

face is always floating)

 

Permissible operating temperature

-25 ... +60 °C

 

 

(horizontal installation)

 

 

-25 ... +40 °C (vertical installation)

 

Dimensions (W x H x D) in mm

40 x 125 x 130

 

Weight

Approx. 350 g

 

Siemens ST PCS 7 · November 2007

9/47

Page 175
Image 175