© Siemens AG 2008

 

 

 

 

 

 

 

Automation systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety-related automation systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection and Ordering Data

Order No.

 

Selection and Ordering Data

Order No.

 

 

 

 

 

 

AS 417F automation system

 

 

 

 

Safety-related SIMATIC PCS 7 automation systems -

 

 

 

 

 

 

with SIMATIC PCS 7

 

 

 

 

Redundant Stations, recommended preferred types

 

 

 

 

 

 

AS Runtime license for 100 POs

 

 

 

 

AS 412FH automation system

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preassembled and tested, without

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with SIMATIC PCS 7

 

 

 

 

 

 

 

CP 443-5 Extended, without sync

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AS Runtime license for 100 POs

 

 

 

 

 

 

 

modules and cables, comprising:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preassembled and tested, without

 

 

 

 

 

 

 

1 x CPU 417-4H with 2 integrated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CP 443-5 Extended, comprising:

 

 

 

 

 

 

 

interfaces (MPI/DP master and

 

 

 

 

2 x CPU 412-3H, each with inte-

 

 

 

 

 

 

 

DP master) and S7 F Systems RT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

grated interface (MPI/DP master)

 

 

 

 

 

 

 

license, 30 MB RAM (15 MB each

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and S7 F Systems RT license,

 

 

 

 

 

 

 

for program and data) as well as

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 x 768 KB RAM (512 KB each for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• UR2 aluminum rack (9 slots)

 

 

 

 

program and 256 KB each for

 

 

 

 

 

 

 

- PS 407 power supply; 10 A for

6ES7 654-8EN01-3BB0

B)

 

 

data) as well as

 

 

 

 

 

 

 

 

 

• Aluminium UR2-H rack

 

 

 

 

 

 

 

120/230 V AC/DC, without

 

 

 

 

 

 

 

 

 

 

 

backup batteries, memory

 

 

 

 

(2 x 9 slots),

 

 

 

 

 

 

 

card 16 MB RAM, 1 x CP 443-

 

 

 

 

4 sync modules for distances up

 

 

 

 

 

 

 

1 communications processor

 

 

 

 

to 10 m and 2 fiber-optic sync

 

 

 

 

 

 

 

for connection to plant bus

 

 

 

 

cables, 1 m

 

 

 

 

 

 

 

- PS 407 power supply; 10 A for

6ES7 654-8EN02-3BB0

B)

 

 

- 2 x 2 PS 407 power supplies;

6ES7 656-8AB31-1EB0

B)

 

 

 

120/230 V AC/DC, without

 

 

 

 

10 A for 120/230 V AC/DC, re-

 

 

 

 

 

 

 

backup batteries, memory

 

 

 

 

dundancy possible, without

 

 

 

 

 

 

 

card 16 MB RAM, 2 x CP 443-

 

 

 

 

backup batteries, 2 memory

 

 

 

 

 

 

 

1 communications processor

 

 

 

 

cards with 1 MB RAM each,

 

 

 

 

 

 

 

for connection to plant bus

 

 

 

 

2 x CP 443-1 communications

 

 

 

 

 

 

 

- PS 405 power supply; 10 A for

6ES7 654-8EN01-3GB0

B)

 

 

processor for connection to

 

 

 

 

 

 

 

 

 

plant bus

 

 

 

 

 

 

 

24 V DC, without backup bat-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 2 x 2 PS 407 power supplies;

 

B)

 

 

 

 

 

teries, memory card 16 MB

 

 

 

 

6ES7 656-8AB32-1EB0

 

 

 

RAM, 1 x CP 443-1 communi-

 

 

 

 

10 A for 120/230 V AC/DC, re-

 

 

 

 

 

 

 

cations processor for connec-

 

 

 

 

dundancy possible, without

 

 

 

 

 

 

 

tion to plant bus

 

 

 

 

backup batteries, 2 memory

 

 

 

 

 

 

 

- PS 405 power supply; 10 A for

6ES7 654-8EN02-3GB0

B)

 

 

cards with 1 MB RAM each,

 

 

 

 

 

 

 

 

 

2 x 2 CP 443-1 communica-

 

 

 

 

 

 

 

24 V DC, without backup bat-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tions processors for connec-

 

 

 

 

 

 

 

teries, memory card 16 MB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tion to plant bus

 

 

 

 

 

 

 

RAM, 2 x CP 443-1 communi-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 2 PS 405 power supplies; 10 A

 

B)

 

 

 

 

 

cations processor for connec-

 

 

 

 

6ES7 656-8AB31-1GB0

 

 

 

tion to plant bus

 

 

 

 

for 24 V DC, without backup

 

 

 

 

 

 

 

 

 

 

 

 

batteries, 2 memory cards with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 MB RAM each, 2 x CP 443-1

 

 

 

 

 

 

 

 

 

 

 

 

communications processors

 

 

 

 

10

 

 

 

 

 

 

 

for connection to plant bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 2 PS 405 power supplies; 10 A

6ES7 656-8AB32-1GB0

B)

 

 

 

 

 

 

 

 

 

for 24 V DC, without backup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

batteries, 2 memory cards with

 

 

 

 

 

 

 

 

 

 

 

 

1 MB RAM each, 2 x 2 CP 443-

 

 

 

 

 

 

 

 

 

 

 

 

1 communications processors

 

 

 

 

 

 

 

 

 

 

 

 

for connection to plant bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B) Subject to export regulations: AL: N, ECCN: EAR99H