Siemens ST PCS 7 Operating systems and diagnostics software, Monitoring/diagnostics functions

Models: ST PCS 7

1 344
Download 344 pages 20.13 Kb
Page 27
Image 27

 

 

© Siemens AG 2007

 

 

 

 

 

 

System-neutral components

 

 

 

 

 

 

SIMATIC PCS 7 Industrial Workstation

 

 

 

 

 

 

Basic hardware

 

 

 

 

 

 

 

 

Technical specifications (cont.)

 

Technical specifications (cont.)

 

2

Operating systems and diagnostics software

ES/OS single station/client

Microsoft Windows XP

 

Professional MUI, 6 languages,

 

selectable: German, English,

 

French, Italian, Spanish, Chinese

Server

Microsoft Windows Server 2003

 

(standard edition) MUI,

 

6 languages, selectable:

 

German, English, French, Italian,

 

Spanish, Chinese

System-tested SIMATIC industrial

SIMATIC PC DiagMonitor

software

 

Monitoring/diagnostics functions

 

 

 

Watchdog

• Monitoring of program execution

 

• Monitoring time adjustable in the

 

software

Temperature

Violation of permissible operating

 

temperature

 

 

Fans

Speed monitoring for:

 

• Front fan

 

• Processor fan

 

• Power supply fan

Displays

Front LEDs

 

• Power (device switched on)

 

• HD (access to hard disk)

 

• Status (fan/temperature

 

monitoring)

Safety

 

 

 

Protection class

Protection class I compliant with

 

IEC 61140

Safety directives

EN 60950-1;

 

UL60950;

 

CSA C22.2 No. 60950-00

Noise level

 

Operation

< 45 dB (A) to DIN 45635

Electromagnetic compatibility (EMC)

Emitted interference (AC)

 

EN 55022 Class B; FCC Class A

 

EN 61000-3-2 Class D,

 

EN 61000-3-3

Immunity to conducted interference

± 2 kV (to IEC 61000-4-4, burst)

on the supply lines

± 1 kV (to IEC 61000-4-5,

 

symmetrical surge)

 

± 2 kV (to IEC 61000-4-5,

 

unsymmetrical surge)

Immunity to interference on signal

± 2 kV (to IEC 61000-4-4, burst,

lines

length > 3 m)

 

± 2 kV (to IEC 61000-4-5, sym-

 

metrical surge, length > 30 m)

Immunity to static discharge

± 4 kV, contact discharge

 

(to IEC 61000-4-2)

 

± 8 kV, atmospheric discharge

 

(to IEC 61000-4-2)

Immunity to high-frequency

1 V/m, 2 to 2.7 GHz

irradiation

10 V/m, 80 MHz to 1 GHz and

 

1.4 to 2 GHz, 80% AM

 

(to IEC 61000-4-3)

 

10 V, 10 kHz to 80 MHz

 

(to IEC 61000-4-6)

Magnetic field

100 A/m, 50 Hz/60 Hz

 

(to IEC 61000-4-8)

 

 

Climatic conditions

 

Temperature

 

Tested according to

 

IEC 60068-2-2, IEC 60068-2-1,

 

IEC 60068-2-14

• Operation

+5 ... +40 °C (no DVD writer

 

operation),

 

+5 ... +35 °C (without limitation)

 

CPU up to 65 W power loss

 

Gradient: max. 10 °C/h,

 

no condensation

• Storage/transport

-20 ... +60 °C

 

Gradient: max. 20 °C/h,

 

no condensation

Relative humidity

Tested according to

 

IEC 60068-2-78, IEC 60068-2-30

• Operation

 

5 ... 80% at 25 °C

 

(no condensation)

 

Gradient: max. 10 °C/h,

 

no condensation

• Storage/transport

5 ... 95% at 25 °C

 

(no condensation)

 

Gradient: max. 20 °C/h,

 

no condensation

Mechanical environmental conditions

 

 

Vibrations

Tested according to

 

IEC 60068-2-6, 10 cycles

• Operation

20 ... 58 Hz, amplitude 0.015 mm;

 

58 ... 200 Hz: 2 m/s²

 

Note: No mechanical interfer-

 

ences are tolerable when writing

 

with CD/DVD writers.

• Storage/transport

5 ... 8.51 Hz, amplitude 3.5 mm;

 

8.51 ... 500 Hz: 9.8 m/s²

Shock

Tested according to

 

IEC 60068-2-27

• Operation

 

Half sine: 9.8 m/s², 20 ms,

 

100 shocks per axis

 

Note: No mechanical interfer-

 

ences are tolerable when writing

 

with CD/DVD writers.

• Storage/transport

Half sine: 250 m/s², 6 ms,

 

1000 shocks per axis

Approvals

 

 

 

CE living accommodation (emitted

EN 61000-6-3:2001

interference)

 

CE industrial areas (noise immunity)

EN 61000-6-2:2005

cULus

60950-1

 

 

Siemens ST PCS 7 · November 2007

2/13

Page 27