© Siemens AG 2008

Automation systems

Fault-tolerant automation systems

 

 

 

Individual components

 

 

 

 

Selection and Ordering Data

Order No.

 

 

 

 

 

 

 

 

Individual components of the fault-tolerant SIMATIC PCS 7

 

 

 

automation systems

 

 

 

 

 

 

 

 

 

 

CPU 412-3H

6ES7 412-3HJ14-0AB0

B)

 

 

RAM 768 KB (512 KB for program

 

 

 

 

and 256 KB for data)

 

 

 

 

Module occupies 2 slots

 

 

 

 

 

CPU 414-4H

6ES7 414-4HM14-0AB0

B)

 

 

 

RAM 2.8 MB (1.4 MB each for

 

 

 

 

 

program and data)

 

 

 

 

 

Module occupies 2 slots

 

 

 

 

 

CPU 417-4H

6ES7 417-4HT14-0AB0

B)

 

 

 

RAM 30 MB (15 MB each for pro-

 

 

 

 

 

gram and data)

 

 

 

 

 

Module occupies 2 slots

 

 

 

 

 

Sync set

 

 

 

 

 

For linking the two redundant 412-

 

 

 

 

 

3H, 414-4H or 417-4H CPUs;

 

 

 

 

 

for distances up to

 

 

 

 

 

• 10 m, consisting of 4 sync mod-

6ES7 656-7XX30-0XX0

 

 

 

 

ules for up to 10 m and 2 fiber-

 

 

 

 

 

optic sync cables, 1 m each

 

 

 

 

 

• 10 km, consisting of 4 sync mod-

6ES7 656-7XX40-0XX0

 

 

 

 

ules for up to 10 km

 

 

 

 

 

Note: please order fiber-optic

 

 

 

 

 

sync cables (2 units) in the re-

 

 

 

 

 

quired length separately.

 

 

 

 

 

Sync module

 

 

 

 

 

For linking the two CPUs 412-3H,

 

 

 

 

 

414-4H or 417-4H;

 

 

 

 

 

two modules required per CPU

 

 

 

 

 

For distances of up to

 

 

 

 

 

• 10 m

6ES7 960-1AA04-0XA0

 

 

 

 

• 10 km

6ES7 960-1AB04-0XA0

 

 

 

 

 

 

 

 

 

 

Sync cable (fiber-optic cable)

 

 

10

 

 

For connecting the two 412-3H,

 

 

 

 

414-4H or 417-4H CPUs;

 

 

 

 

 

each redundant automation sys-

 

 

 

 

 

tem requires 2 cables

 

 

 

 

 

• 1 m

6ES7 960-1AA04-5AA0

 

 

 

 

• 2 m

6ES7 960-1AA04-5BA0

 

 

 

 

• 10 m

6ES7 960-1AA04-5KA0

 

 

 

 

 

 

 

 

 

 

Other lengths

auf Anfrage

 

 

 

 

Memory Card RAM

 

 

 

 

 

• 1 MB

6ES7 952-1AK00-0AA0

 

 

 

 

• 2 MB

6ES7 952-1AL00-0AA0

 

 

 

 

• 4 MB

6ES7 952-1AM00-0AA0

 

 

 

 

• 8 MB

6ES7 952-1AP00-0AA0

 

 

 

 

• 16 MB

6ES7 952-1AS00-0AA0

 

 

 

 

• 64 MB

6ES7 952-1AY00-0AA0

 

 

 

 

Memory Card Flash-EPROM

 

 

 

 

 

Only required to update firmware.

 

 

 

 

 

Alternative: firmware update via

 

 

 

 

 

the engineering system

 

 

 

 

 

• 8 MB

6ES7 952-1KP00-0AA0

 

 

 

 

 

 

 

Selection and Ordering Data

Order No.

 

 

CP 443-1

6GK7 443-1EX11-0XE0

 

 

Communications processor for

 

 

 

connection of SIMATIC S7-400 to

 

 

 

Industrial Ethernet through

 

 

 

TCP/IP, ISO and UDP; for S7 com-

 

 

 

munication, S5-compatible com-

 

 

 

munication (SEND/RECEIVE) with

 

 

 

FETCH/WRITE with or without

 

 

 

RFC 1006, diagnostics expan-

 

 

 

sion, Multicast, commissioning

 

 

 

through LAN 10/100 Mbit/s, with

 

 

 

electronic manual on CD-ROM

 

 

 

CP 443-5 Extended

6GK7 443-5DX04-0XE0

 

 

Communications processor for

 

 

 

connection of SIMATIC S7-400 to

 

 

 

PROFIBUS as DP master or for

 

 

 

S7 communication, for increasing

 

 

 

the number of DP lines, for data

 

 

 

set routing with SIMATIC PDM

 

 

 

and for 10-ms time stamp,

 

 

 

electronic manual on CD;

 

 

 

module occupies 1 slot

 

 

 

PS 407 power supply module;

6ES7 407-0KA02-0AA0

 

 

10 A

 

 

 

120/230 V AC/DC; 5 V DC/10 A,

 

 

 

24 V DC/1 A;

 

 

 

with battery compartment for

 

 

 

2 backup batteries, module occu-

 

 

 

pies 2 slots

 

 

 

PS 407 power supply module;

6ES7 407-0KR02-0AA0

 

 

10 A, redundant design

 

 

 

120/230 V AC/DC; 5 V DC/10 A,

 

 

 

24 V DC/1 A;

 

 

 

with battery compartment for

 

 

 

2 backup batteries, module occu-

 

 

 

pies 2 slots

 

 

 

PS 407 power supply module;

6ES7 407-0RA02-0AA0

 

 

20 A

 

 

 

120/230 V AC/DC; 5 V DC/20 A,

 

 

 

24 V DC/1 A;

 

 

 

with battery compartment for

 

 

 

2 backup batteries, module occu-

 

 

 

pies 2 slots

 

 

 

PS 405 power supply module;

6ES7 405-0KA02-0AA0

 

 

10 A

 

 

 

24 V DC; 5 V DC/10 A, 24 V

 

 

 

DC/1 A;

 

 

 

with battery compartment for

 

 

 

2 backup batteries, module occu-

 

 

 

pies 2 slots

 

 

 

PS 405 power supply module;

6ES7 405-0KR02-0AA0

B)

 

10 A, redundant design

 

 

 

24 V DC; 5 V DC/10 A, 24 V

 

 

 

DC/1 A;

 

 

 

with battery compartment for

 

 

 

2 backup batteries, module occu-

 

 

 

pies 2 slots

 

 

 

PS 405 power supply module;

6ES7 405-0RA02-0AA0

 

 

20 A

 

 

 

24 V DC; 5 V DC/20 A, 24 V

 

 

 

DC/1 A;

 

 

 

with battery compartment for

 

 

 

2 backup batteries, module occu-

 

 

 

pies 2 slots

 

 

 

Backup battery

6ES7 971-0BA00

 

 

Type AA, 2.3 Ah

 

 

 

 

 

 

B) Subject to export regulations: AL: N, ECCN: EAR99H

10/22

Siemens ST PCS 7 · Update November 2008

Page 202
Image 202
Siemens ST PCS 7 manual 10/22, Automation systems