send out the alarm message.
•Network is switched off: when the network connection of DVR system is lost, the system will send out the alarm message.
•Hard Disk failed: when the hard disk can’t work normally, the system will send out the alarm message.
•Temperature: set a temperature limited of system for system to alarm. When DVR system temperature is over the temperature limited, the system will send out the alarm.
iTemperature setting only supports on NV DOM 6000 Express card.
•Illegal Entry: any objects move between selected regions which user has set up in Object Counting section (see also Chapter 4.2.1), the system will send out the alarm. Select the entry (object moves from region 1 to 2 or from region 2 to 1) and camera for system alarm detection.
-Enable/disable the POS Keyword check box, to scan the data from the POS if it matches the keyword (see also Chapter 4.9.11).
-Enable/disable the Alarm Message check box, to active with external alarm message by your own program. For the detail configuration, please contact the local reseller.
6.In (5) Alarm Reset, click the camera number (use W and X to select the alarm) to set the reset condition of alarm. Once alarm is reset, all alarm action will stop at the moment. If the sensor normal status is high, set the sensor condition to low.
7.In (6) Action, you may now set the alarm action for the system to perform when the alarm condition is activated.
-Launch E-Map
Display mini Emap screen.
-TV Out
Switch to only display the video on TV from where the alarm is activated.
-Enlarge Camera View
Switch to only display video in Preview/Advanced mode from where the alarm is activated.
-Send E-mail
Send an electronic text message. To setup click Detail (see also To Setup Send
-File Transmission via FTP
Upload file to remote computer thru FTP (File Transfer Protocol). To setup click Detail (see also To Setup FTP).
-Start Recording
Record the video from the selected camera. To setup click Detail (see also To Setup Alarm Recording).
-Alarm SOP (Standard Operation Procedure)
List the instructions to inform the person of what to do when the alarm is activated. To
120