4.11.1 Data Channels

The function of the Data Channels is to store, report, and view data from the analyzer. The data may consist of carbon monoxide concentration, or may be diagnostic data, such as the sample flow or detector output.

The M300 comes pre-programmed with a set of useful Data Channels for logging carbon monoxide concentration and predictive diagnostic data. The default Data Channels can be used as they are, or they can be changed by the user to fit a specific application. They can also be deleted to make room for custom user-programmed Data Channels.

The data in the default Data Channels can be viewed through the SETUP-DAS-VIEWmenu. Use the PREV and NEXT buttons to scroll through the Data Channels and press VIEW to view the data. The last record in the Data Channel is shown. Pressing PREV and NEXT will scroll through the records one at a time. Pressing NX10 and PV10 will move forward or backward 10 records. For Data Channels that log more than one parameter, such as PNUMTC, buttons labeled <PRM and PRM> will appear. These buttons are used to scroll through the parameters located in each record.

The function of each of the default Data Channels is described below:

CONC: Samples carbon monoxide concentration (Low Range) at one minute intervals and stores an average every hour with a time and date stamp. Readings during calibration and calibration hold off are not included in the data. The last 800 hourly averages are stored.

PNUMTC: Collects sample flow and sample pressure data at five minute intervals and stores an average once a day with a time and date stamp. This data is useful for monitoring the condition of the pump and critical flow orifice(sample flow) and the sample filter(clogging indicated by a drop in sample pressure) over time to predict when maintenance will be required. The last 360 daily averages (about 1 year) are stored.

CALDAT: Logs new slope and offset every time a zero or span calibration is performed. This Data Channel also records the instrument reading just prior to performing a calibration. Note: this Data Channel collects data based on an event(a calibration) rather than a timer. This Data Channel will store data from the last 200 calibrations. This does not represent any specific length of time since it is dependent on how often calibrations are performed. As with all Data Channels, a time and date stamp is recorded for every data point logged.

P/N 02163G1 Teledyne API Model 300 CO Analyzer Instruction Manual - Page 43

Page 49
Image 49
Teledyne 300 instruction manual Data Channels

FAQ

What is the function of Data Channels?

The function of the Data Channels is to store, report, and view data from the analyzer.

Can the default Data Channels be changed?

Yes, the default Data Channels can be changed by the user to fit a specific application.

How can I view the data in the default Data Channels?

The data in the default Data Channels can be viewed through the SETUP-DAS-VIEW menu.