e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 148 November 2003 © TOSHIBA TEC
<<PM support mode related code>>
The management items at PM support mode can also be operated at setting mode (08).
The following items are displayed or set by using sub-codes at PM management setting in the
table below.
<Sub-codes>
0: Present number of output pages
-Means the present number of output pages.
1: Recommended number of output pages for replacement
-Means the recommended number of output pages for replacement.
2: Number of output pages at the last replacement
-Means the number of output pages at the last replacement.
3: Present drive counts
-Means the present drive counts (1 count = 2 seconds).
4: Recommended drive counts to be replaced
-Means the recommended drive counts for replacement (1 count = 2 seconds).
5: Driving counts at the last replacement
-Means the drive counts at the last replacement.
6: Present output pages for control
-Means the present number of output pages for controlling.
7: Present drive counts for control
-Means the present drive counts for controlling (1 count = 2 seconds).
8: Number of times replaced
-Counts up when clearing the counter of each unit in the PM Support Mode Screen.
Notes:
• Sub-code 3 is equivalent to sub-code 7.
• When the value of sub-code 3 is changed, the value of sub-code 7 is also updated and vice versa.
• When "0" is set at one of sub-codes 0, 3, 6 and 7, the rest of them are automatically updated to "0".