November 2003 © TOSHIBA TEC 6 - 53 e-STUDIO3511/4511 FIRMWARE UPDATING
“Update Failed.” is displayed at the bottom of the LCD screen when the updating is not
completed properly. Turn OFF the power, and then check the following items. After confirming
and clearing the problems, restart updating from the beginning.
Does the USB storage device meet the conditions to be used for updating ( Page 6-45)?
Is the data file written properly on the USB storage device?
Is the USB storage device installed properly?
Do the USB storage device and equipment operate properly?
* When the updating of the NIC firmware is failed, an error message is displayed as the figure
below. Turn OFF the power and then check the above-mentioned items. After confirming them,
select only “4. NIC Firmware Update” and restart updating from the beginning. This may
complete the updating properly.
04/10
NIC error message