November 2003 © TOSHIBA TEC 6 - 37 e-STUDIO3511/4511 FIRMWARE UPDATING
(a) Update procedure
Important:
• Do not operate the equipment or send a print job to the equipment during the update. This interferes
the updating operation and the firmware may not be written properly.
Do not turn OFF the power of equipment or PC during the update. The data could be damaged and not
to be continued to function properly.
• When using FSMS, set “1” at FSMS permission code (08-258) in the Setting Mode (08) in advance.
• The data file (tz file format) of each firmware is recommended to save at the local drive in the PC (C
drive, etc.) where FSMS program is installed.
(1) Connect the equipment and PC with the cable.
[USB connection] [RS-232C connection]
* Connect the cable to the RS-232C connector in RS-232C connection after taking off the
connector cover of the equipment.
* Connect the PC end of the cable to the USB port or RS-232C port on the PC.
(2) Turn ON the power of the equipment.
Tip:
When updating with FSMS, updating can be performed in any of the normal mode, Adjustment Mode (05) and
Setting Mode (08). To avoid an interruption during the update, using the Setting Mode (08) is recommended.
(3) Turn ON the power of the PC.
(4) Activate FSMS.
Select “TOSHIBA FSMS” starting with the Start menu.
USB connector (device) USB cable RS-232C connector RS-232C cable