e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 22 November 2003 © TOSHIBA TEC
*1 Turn OFF the power after using the self-diagnosis mode, and leave the equipment to the user.• Test mode (03): Refer to “2.2.1. Input check (test mode 03)” and “2.2.2. Output check (test mode 03)”.• Test print mode (04): Refer to “2.2.3. Test print mode (04)”.• Adjustment mode (05): Refer to “2.2.4. Adjustment mode (05)”.• Setting mode (08): Refer to “2.2.5. Setting mode (08)”.• List print mode (9S): The procedure varies depending on the code.State transition diagram of self-diagnosis modes
[9] [START]
[POWER]
(Code)
101: Adjustment mode (05)
102: Setting mode (08)
(Code)
103: PM support mode
104: Stored information of pixel counter (toner cartridge reference)
105: Stored information of pixel counter (service technician reference)
106: Error history
[Digital keys]
Key in the first
code to be printed
[START] [Digital keys]
Key in the last
code to be printed
[START] [START]
List starts to
be printed
[POWER] OFF/ON
(Exit)

[6][START]

[POWER]

[POWER] OFF/ON

(Exit)

(Code) [START]

(Operation started)

2: PM Support Screen

Warming up Control panel
check mode Test mode Test print
mode
Adjustment
mode Setting
mode
List print
mode PM support
mode
Firmware
update mode
[POWER]
ON
Normal
Ready
[POWER]
OFF
To user
[0][1] [0][3] [0][4] [0][5] [0][8] [9][START] [6][START] [8][9]
*1
• PM support mode (6S):• Firmware update mode (89): Refer to “6. FIRMWARE UPDATING”.