e-STUDIO3511/4511 ADJUSTMENT 3 - 86 November 2003 © TOSHIBA TEC
(11) Change the settings of bits 6 through 8 on SW504 referring to the following table.
• If the width adjustment is 0
The stitching position and the folding position match, requiring no change.
• If for “positive width adjustment”
Set SW504 so that the difference resulting from subtraction of the interval from the appropriate
setting in the table below is provided.
Example: If SW504 is currently set to +2 and the interval is +1 mm, set SW504 to reflect - 2.
• If for “negative width adjustment”
Set SW504 so that the sum resulting from addition of the interval from the appropriate setting
in the table below is provided.
Example: If SW504 is currently set to -1 and the interval is -0.5mm, set SW504 to reflect +1.
DIPSW1 bit settings
Bit 6 Bit 7 Bit 8
OFF ON ON
OFF ON OFF
OFF OFF ON
OFF OFF OFF
ON OFF ON
ON ON OFF
ON ON ON
Setting
(in units of 0.5 mm)
+3
+2
+1
0
-1
-2
-3
Do not use the following setting
Bit 6 Bit 7 Bit 8
ON OFF OFF
(12) Set SW504 bits 1 to 4 to OFF.