e-STUDIO3511/4511 ADJUSTMENT 3 - 86 November 2003 © TOSHIBA TEC
(11) Change the settings of bits 6 through 8 on SW504 referring to the following table.
If the width adjustment is 0
The stitching position and the folding position match, requiring no change.
If for “positive width adjustment”
Set SW504 so that the difference resulting from subtraction of the interval from the appropriate
setting in the table below is provided.
Example: If SW504 is currently set to +2 and the interval is +1 mm, set SW504 to reflect - 2.
If for “negative width adjustment”
Set SW504 so that the sum resulting from addition of the interval from the appropriate setting
in the table below is provided.
Example: If SW504 is currently set to -1 and the interval is -0.5mm, set SW504 to reflect +1.
DIPSW1 bit settings
Bit 6 Bit 7 Bit 8
OFF ON ON
OFF ON OFF
OFF OFF ON
OFF OFF OFF
ON OFF ON
ON ON OFF
ON ON ON
Setting
(in units of 0.5 mm)
+3
+2
+1
0
-1
-2
-3
Do not use the following setting
Bit 6 Bit 7 Bit 8
ON OFF OFF
(12) Set SW504 bits 1 to 4 to OFF.