e-STUDIO3511/4511 ADJUSTMENT 3 - 14 November 2003 © TOSHIBA TEC
A
21
6
1
B, E
D
C
6
2
22
Feeding direction
[Grid pattern]
Fig. 3-401
<Adjustment order>
[0] [5] [Power ON] [1] ([3](05-445, 498) for duplexing) [FAX]
A: 05-401 (Lower drawer, A3/LD) 200±0.5 mm (0.05 mm/step)
B: 05-411 (Lower drawer, A3/LD) 52±0.5 mm (0.04 mm/step)
Key in the same value for 05-410.
C: 05-421 (Lower drawer, A3/LD) 200±0.5 mm (0.5 mm/6 steps)
D: 05-440 (Upper drawer, A4/LT) 52±0.5 mm (0.2 mm/step),
441 (Lower drawer, A3/LD),
442 (Bypass feed, A4/LT),
443 (LCF, A4/LT), 444 (PFP, A4/LT),
445 (Duplexing, A3/LD)
E: 05-498-0 (Lower drawer, A3/LD), 52±0.5 mm (0.04 mm/step)
498-1 (Upper drawer, A4/LT)