November 2003 © TOSHIBA TEC 2 - 9 e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
CC50
CC60
CC80
CC90
CCA0
CCB0
CCD0
CCE0
CCF0
CE00
CE10
CE20
CE40
CE50
CE90
CEA0
CEB0
Horizontal registration motor abnormality: Horizontal registration
motor is not rotating or puncher is not shifting normally.
[MJ-1023/1024 (when MJ-6004 is installed)]
Punch motor abnormality: Punch motor is not rotating or
puncher is not shifting normally. [MJ-1023/1024 (when MJ-6004
is installed)]
Front alignment motor abnormality: Front alignment motor is not
rotating or front aligning plate is not moving normally. [MJ-1022]
Front aligning plate motor abnormality: Front aligning plate
motor is not rotating or aligning plate is not moving normally.
[MJ-1023/1024]
Upper stack tray lift motor abnormality: The upper stack tray lift
motor is not rotating or the upper stack tray is not moving
normally. [MJ-1022]
Lower stack tray lift motor abnormality: The lower stack tray lift
motor is not rotating or the lower stack tray is not moving
normally. [MJ-1022]
Rear jogging motor abnormality: The rear jogging motor is not
rotating or the rear jogging plate is not moving normally. [MJ-1022]
Stack ejection motor abnormality: Stack ejection motor or stack
ejection roller is not rotating normally. [MJ-1023/1024]
Paper trailing edge assist motor abnormality: Paper trailing
edge assist motor is not rotating or paper trailing edge assist is
not moving normally. [MJ-1023/1024]
Gear changing motor abnormality: Gear changing motor is not
rotating normally. [MJ-1023/1024]
Communication error between finisher and punch unit: Commu-
nication error between finisher controller PC board and punch
controller PC board [MJ-1023/1024 (when MJ-6004 is installed)]
Image quality sensor abnormality (OFF level): The output value
of this sensor is out of a specified range when sensor light
source is OFF.
Image quality sensor abnormality (no pattern level): The output
value of this sensor is out of a specified range when the image
quality control test pattern is not formed.
Image quality control test pattern abnormality: The test pattern
is not formed normally.
Temperature/humidity sensor abnormality: The output value of
this sensor is out of a specified range.
Drum thermistor abnormality: The output value of the drum
thermistor is out of a specified range.
Revolver home position detection abnormality: It cannot detect
that the revolver is at its home position.
Black developer unit lifting movement abnormality: The black
developer unit does not move up or down normally (lifting cam
does not operate normally).
Finisher related
service call
Image control
related service call
Copy process
related service call
Trouble-
shooting
Error code Classification Contents
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.16
Ch. 5.1.17
Ch. 5.1.17
Ch. 5.1.17
Ch. 5.1.17
Ch. 5.1.17
Ch. 5.1.18
Ch. 5.1.18