November 2003 © TOSHIBA TEC 3 - 39 e-STUDIO3511/4511 ADJUSTMENT
Remarks
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
The larger the value is, the
darker the dark side becomes.
Acceptable values: 0 to 255
(Default: 20)
The larger the value is, the
lighter the light side becomes.
Acceptable values: 0 to 255
(Default: 20)
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
Item to be
adjusted
Manual density
center value
Manual density
dark step value
Manual density
light step value
Automatic density
Text
846
856
851
861
Photo
847
857
852
862
Text/Photo
845
855
850
860
3.7.2 Density adjustment (Black Mode)
Adjusts the center density and the variation of density adjustment buttons.
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value (acceptable values: 0 to 255).
(To correct the value once keyed in, press the [CLEAR] button.)
(4) Press the [ENTER] or [INTERRUPT] button to store the value in memory. The equipment goes
back to the ready state.
(5) Let the equipment restart and perform scanning job.
(6) If the desired image has not been attained, repeat step (1) to (5).
Black
Color
mode
Original mode
<Adjustment Mode (05)>