November 2003 © TOSHIBA TEC 5 - 141 e-STUDIO3511/4511 TROUBLESHOOTING
04/09
(12)Turn the power OFF.
(13)Turn the power ON.
(14)Set the dial type. [USER FUNCTIONS] [ADMIN] [FAX] [INITIAL SETUP]
5.3.3 Replacing SLG board
<CAUTION IN REPLACING SLG BOARD>
When the SLG board has been replaced, “Data transfer of characteristic value of scanner / SYS board
SLG board (05-363)” must be performed.
5.3.4 NVRAM replacing and clearing
<CAUTION IN REPLACING AND CLEARING NVRAM>
When NVRAM has been replaced or cleared (”System all clearing (08-669)”), the following adjustments
must be performed.
1. Perform “Data transfer of characteristic value of scanner / SLG board SYS board (05-364)”.
2. Perform “Image quality control initialization (05-396)” ( Chapter 3.3), and then perform
“Automatic gamma adjustment (05-1642, 1000 and 1002)” consecutively ( Chapters 3.5.1
and 3.6.1).