e-STUDIO3511/4511 ADJUSTMENT 3 - 4 November 2003 © TOSHIBA TEC
Humidity(%)
29.9 or below
30.0-44.9
45.0-59.9
60.0-74.9
75.0 or above
K
2.47
2.49
2.50
2.69
2.86
Note:
Since the adjustments for “Y”, “M” and “C” are controlled by the light sensor, the humidity
correction is not performed.
(B): Current sensor voltages (V)
• In case of single-color adjustment, press the [ENTER] button to store the adjustment results in
memory when the control value is displayed. In case of multiple-color adjustment, it is automati-
cally proceeded to the adjustment of next color. When the adjustments of all colors have finished
and [ENTER] is lit, press [ENTER] button to store the adjustment results in memory.
(6) Standard of adjustment value range
(A): Adjustment reference voltages (V)
Y
1.25
M
1.25
C
1.25
Note:
Since the adjustments for “Y”, “M” and “C” are controlled by the light sensor, the humidity
correction is not performed.
(7) Turn the power OFF.
(8) Install the toner cartridges.
Humidity(%)
29.9 or below
30.0-44.9
45.0-59.9
60.0-74.9
75.0 or above
K
2.37-2.57
2.39-2.59
2.40-2.60
2.59-2.79
2.76-2.96
Y
1.15-1.35
M
1.15-1.35
C
1.15-1.35