November 2003 © TOSHIBA TEC 3 - 3 e-STUDIO3511/4511 ADJUSTMENT
•In 30 to 60 seconds, the current sensor voltage (V) in (B) is converged. Then the sensor output
control value (bit value) corresponding to the initial developer material is displayed in (C).
(B): Current sensor voltage (V)
(C): Sensor output control value (bit value)
(A): Target value (V) for adjustment reference voltage
K:xxxV
K:yyy
K:zzzV
(B)
(C)
(A)
Note:
Be careful that the values in (A), (B) and (C) vary with humidity.
•In case of single-color adjustment, press the [ENTER] button to store the adjustment results in
memory when the control value is displayed. In case of multiple-color adjustment, it is automati-
cally proceeded to the adjustment of next color.
(5) Adjustments for “Y”, “M” and “C” (light sensor control)
• In 15 to 45 seconds, the following message will be displayed (The time varies with the number
of colors to be adjusted).
(B): Current sensor voltage (V)
(C): No display
(A): Target value (V) for adjustment reference voltage
Y:
Y:
(B)
(C)
(A)
Note:
The current sensor voltage (V) shown in (B) automatically changes, gradually approaching the
target value for adjustment reference voltage shown in (A).
• After approx. 5 seconds have passed, the current sensor voltage (V) in (B) is converged. Then
the sensor output control value (bit value) corresponding to the initial developer material is
displayed in (C).
(B): Current sensor voltage (V)
(C): Sensor output control value (bit value)
(A): Target value (V) for adjustment reference voltage
Y:xxxV
Y:yyy
Y:zzzV
(B)
(C)
(A)