November 2003 © TOSHIBA TEC 6 - 3 e-STUDIO3511/4511 FIRMWARE UPDATING
[Jig board: PWA-DWNLD-350-JIG2 (48 MB)] [Jig board: PWA-DWNLD-350-JIG1 (16 MB)]
Important:
• The download jig (PWA-DWNLD-350-JIG) has two types having different ROM capacity. ROM capacity
for each jig is as follows.
* “PWA-DWNLD-350-JIG2 (48 MB)” is substitutable for “PWA-DWNLD-350-JIG1 (16 MB)”
• The download jig (PWA-DWNLD-350-JIG) is different from the existing jigs. The ROM is installed on
the board directly. Therefore, ROM writer adapter (PWA-DL-ADP-350) is required to write the data to
these ROMs. Refer to the following to write the data.
6.1.3 Writing the data to the download jig (PWA-DWNLD-350-JIG)
Download jig
PWA-DWNLD-350-JIG2 (48 MB)
PWA-DWNLD-350-JIG1 (16 MB)
ROM capacity
8 MB x 6
8 MB x 2
Application
Updating the master data
Updating the system ROM, engine ROM,
scanner ROM, NIC ROM
Connector
(for SYS board
connection)
Connector
(for ROM writer
adapter connection)
ROM4
ROM5
ROM6
ROM1
ROM2
ROM3
ROM1
ROM2
Connector
ROM
LED
Connector
(for SYS board
connection)
Connector
(for ROM writer
adapter connection)
Mark for ROM installation direction
[Jig board:K-PWA-DLM-320]
Important:
Pay attention to the direction of the ROM.