e-STUDIO3511/4511 FIRMWARE UPDATING 6 - 32 November 2003 © TOSHIBA TEC
(4) Remove the cover plate.
(5) Connect the download jig with the jig connector (CN602) on the FAX board.
(6) Turn ON the power while [0] button and [8] button are pressed simultaneously.
Updating starts automatically and the LED on the download jig lights.
(7) After the update is completed properly, the LED on the download jig blinks. The LED starts
blinking in approx. 30 sec. since the update starts. It is assumed that the update is failed if it does
not start blinking even though 1 min. has passed. In this case, turn OFF the power and check
the blinking items. Then, clear the problem and restart updating from the beginning.
• Is the download jig connected properly?
• Is the ROM installed to the download jig properly?
• Is the updating data written on the ROM of the download jig properly?
• Do the download jig and the equipment operate properly?
(8) Turn OFF the power, remove the download jig and install the cover plate and the connector cover.
Cover plate
Connector