e-STUDIO3511/4511 FIRMWARE UPDATING 6 - 16 November 2003 © TOSHIBA TEC
(b) Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that
the data was overwritten properly.
<Updating System ROM>
08-900: System ROM version
08-920: FROM basic section software version
08-921: FROM internal program version
08-922: UI data fixed section version
08-923: UI data common section version
08-930: Version of UI data in FROM displayed at power ON
<Updating Engine ROM>
08-903: Engine ROM version
<Updating Scanner ROM>
08-905: Scanner ROM version
<Updating NIC ROM>
08-916: NIC ROM version
04/10
(10) Turn OFF the power, remove the download jig and install the cover plate and the connector
cover.
(11) Perform the initialization of the updating data (NVRAM updating).
a. Turn ON the power while [0] button and [8] button are pressed simultaneously.
b. Key in “947”, and then press the [START] button.
c. Press the [INITIALIZE] button.