e-STUDIO3511/4511 ADJUSTMENT 3 - 22 November 2003 © TOSHIBA TEC
Text/Photo
503
508
505
514
Text
504
510
507
515
Printed Image
1552
1562
1572
1582
Photo
1553
1563
1573
1583
Map
1554
1564
1574
1584
Text/Photo
1550
1560
1570
1580
Text
1551
1561
1571
1581
3.5.2 Density adjustmentThe center density and the density variation controlled by density adjustment keys can be adjusted asfollows.
Make a test copy and compare the image obtained with the current settings; if necessary, make
adjustment using the following procedure.
Full Color
Color
mode Remarks
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
The larger the value is, the
darker the dark side becomes.
Acceptable values: 0 to 255
(Default: 20)
The larger the value is, the
lighter the light side becomes.
Acceptable values: 0 to 255
(Default: 20)
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
Item to be
adjusted
Manual density mode
center value
Manual density mode
dark step value
Manual density mode
light step value
Automatic density
mode
Black
Color
mode
Original mode Remarks
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
The larger the value is, the
darker the dark side becomes.
Acceptable values: 0 to 255
(Default: 20)
The larger the value is, the
lighter the light side becomes.
Acceptable values: 0 to 255
(Default: 20)
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
Item to be
adjusted
Manual density mode
center value
Manual density mode
dark step value
Manual density mode
light step value
Automatic density
mode
Photo
501
509
506
512
<Adjustment Mode (05)>
Original mode
<Adjustment Mode (05)>