Appendix 5

System Mode

A5.3 Self-Diagnostic Test (Cont.)

Note:

Make sure that the Top Cover is closed before starting the print head check.

A5.4 Parameter

Setting

Notes:

When pressing the FEED and RESTART keys at the same time

in the parameter setting, the message returns to “<2>

PARAMETER SET”.

If holding the FEED or RESTART key for 0.5 seconds

or longer in the parameter setting, the key is entered continuously.

A changed parameter becomes enabled by pressing the PAUSE key and is stored in memory until the printer is turned off.

Note:

Use the FEED or RESTART key to select a desired value or option.

Checking If There is any Problem with the Print Head

When the Maintenance Counter/Parameter Settings is printed, the message returns to “<1> DIAG.”. Press the PAUSE key three times.

<1>DIAG. V1.0

The printer is ready to check the print heads to see if there are problems with the print head. Press the PAUSE key to start.

HEAD CHECK

The printer starts checking the print heads. It takes about 25 seconds to complete the print head check.

CHECKING

If there is no problem with the print head, the print head check is complete.

Press the PAUSE key to return to “<1> DIAG.”.

NORMAL END

If there is a problem with the print head, the message indicates which print head has the problem.

HEAD ERROR KMC

This example indicates that there are problems with the print heads for black, magenta and cyan.

The Parameter Setting menu contains the following:

Adjustments for a print start position.

Adjustments for a cut position.

Adjustments for a distance of back feed.

Adjustments for a print stop position.

Adjustments for an X-coordinate.

Adjustments for a print density (Y, M, C and K).

Modifies the alignment in X direction (Y, M, C and K).

Modifies the alignment in Y direction (Y, M, C and K).

Initiates printouts of X/Y direction fine adjustment (Caliper-shaped pattern).

Selection of the character code, “0” font and Control code.

Adjustments for a pulse motor speed.

Selection of the print head to be used (Y, M, C and K).

Selection of the ribbon type (Y, M, C and K).

Selection of the Euro code.

<1>DIAG. V1.0

While pressing the FEED and PAUSE keys at the same time, turn on the printer. Hold both keys until the “<1> DIAG.” message appears. Press the FEED key.

<2>PARAMETER SET

The printer is at the start of the Parameter Setting menu.

92

Page 100
Image 100