Appendix 2 | DIP Switches |
A2.1 DIP Switch A
Notes:
∙The shaded areas are the factory default settings.
“OFF” means “OPEN”.
∙See A2.3 for further information about the ribbon near end detection.
No. | ON/OFF | Function | |||||
|
|
|
|
|
|
|
|
1 |
|
| OFF |
|
| Must be set to OFF | |
|
| ON |
|
| |||
|
|
|
|
|
| ||
2 |
|
| OFF |
| Without | Cutter Module | |
|
| ON |
| With | |||
|
|
|
|
| |||
3 |
|
| OFF |
| Online Mode | Must be set to OFF | |
|
| ON |
| Program loading mode | |||
|
|
|
|
| |||
| 4 |
|
|
| 5 |
|
|
| OFF |
|
| OFF | No detection of ribbon |
| |
|
|
| near end. |
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
| Pause when the ribbon |
|
| ON |
|
| OFF | near end is detected. |
| |
|
|
| The ribbon near end status |
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
| is sent to the PC. |
|
4 |
|
|
|
|
|
|
|
|
|
|
|
| Continues printing when |
| |
|
|
|
|
|
| the ribbon near end is | Ribbon near end |
| OFF |
|
| ON | detected. | detected. | |
5 |
|
|
|
|
| The ribbon near end status |
|
|
|
|
|
|
| is not sent to the PC. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Continues printing when |
|
|
|
|
|
|
| the ribbon near end is |
|
| ON |
|
| ON | detected. |
| |
|
|
|
|
|
| The ribbon near end status |
|
|
|
|
|
|
| is sent to the PC. |
|
|
|
|
|
|
|
|
|
| 6 |
| 7 | 8 |
| Language to display | |
| OFF |
| OFF | OFF | English | LCD error message | |
6 | ON |
| OFF | OFF | German |
| |
| OFF |
| ON | OFF | French |
| |
7 | ON |
| ON | OFF | Dutch |
| |
| OFF |
| OFF | ON | Spanish |
| |
8 | ON |
| OFF | ON | Japanese |
| |
| OFF |
| ON | ON | Not used |
| |
| ON |
| ON | ON | Not used |
|
80