Chapter 2 Printer Installation

2.8.4Installing the Ribbon Tension Sheet

Note:

Do not reinstall the Ribbon guide Lever, Ribbon Guide Lever Shaft and the D-3x6 screw because they are not used after the ribbon tension sheet has been installed.

1Remove the Ribbon Guide Lever from the Ribbon Cassette by removing the screw.

2Fit the bosses on the Sheet Fixing Plate into the holes of the Ribbon Tension sheet and the aluminum frame. Secure them with the three D-3x5 screws.

Ribbon Cassette

Aluminum Frame

 

 

Ribbon Guide Level

 

Ribbon Guide

D-3x5

Level Shaft

Bosses D-3x6

(A)

(B)

Sheet Fixing Plate

Ribbon Tension Sheet

(A)

(B)