Appendix 5

System Mode

A5.6 RAM Clear

Notes:

When pressing the FEED and RESTART keys at the same time in RAM Clear or “NO RAM CLEAR”, the message returns to “<4> RAM CLEAR”.

After RAM clear, the following items are still stored: X/Y direction fine adjustment value, total label distance covered, sensor adjustment value and data in the flash memory.

The RAM Clear menu contains the following:

Maintenance Counter clear.

Parameter clear.

Print Step clear.

<1>DIAG. V1.0

While pressing the FEED and PAUSE keys at the same time, turn on the printer. Hold both keys until the “<1> DIAG.” message appears. Then press the FEED key three times.

<4>RAM CLEAR

RAM clear functions are ready to be performed. Press the PAUSE key.

NO RAM CLEAR

Note:

See A5.7.7 for further information about the initial values after clearing the Maintenance Counter.

Press the PAUSE key not to perform a RAM clear. The message returns to “<4> RAM CLEAR”.

Press the PAUSE key. “NO RAM CLEAR” appears again. Press the FEED key.

Clearing the Maintenance Counter

MAINTE CNT CLEAR

The Maintenance Counter can be cleared by pressing the PAUSE key.

COMPLETE

The Maintenance Counter is cleared.

The printer must be turned off to exit this mode.

Note:

See A5.7.8 for further information about the initial values after clearing the parameters.

Clearing the Parameter

NO RAM CLEAR

When “<4> RAM CLEAR” is shown, press the PAUSE key. “NO RAM CLEAR” appears again. Press the FEED key twice.

PARAMETER CLEAR

The parameters can be cleared by pressing the PAUSE key.

COMPLETE

The parameters are cleared.

The printer must be turned off to exit this mode.

104

Page 112
Image 112