Appendix 5

System Mode

Specifying the Control Code Selection Method

CODE AUTO

Note:

See A5.7.4 for further information about the pulse motor speed.

Select the Control Code methods: “AUTO” (automatic selection), or “ESC, LF, NUL” or “{, ,}” or (manual selections).

After selecting the method, press the PAUSE key.

PULSE MOTOR AUTO

Select one of the following pulse motor speeds: AUTO or 104. If selecting “AUTO”, the pulse motor cycle varies depending on the operating temperature. If “104” is selected, the pulse motor cycle is fixed at 104%.

After selecting the pulse motor speed, press the PAUSE key.

Specifying the Euro Code

EURO CODE

B0

Select one of the following Euro codes: FFH, FEH to B0H, B0H to 21H or 20H.

After selecting the Euro code, press the PAUSE key. The message returns to “PRINTER PARA”.

Adjusting the Pulse Motor Speed

PRINTER PARA

After “PRINTER PARA” appears, press the FEED key.

PM ADJUST

Note:

Use the FEED or RESTART key to select a desired value.

To make a fine adjustment of the pulse motor speed, press the PAUSE key.

PM ADJ.

+0

The acceptable values are -60 to +60. As the value becomes lower, the motor speed becomes faster.

After adjusting the pulse motor speed, press the PAUSE key. The message returns to “<2> PARAMETER SET”.

99