UBCD396XT

26.Tone Out mode

With the tone out feature, the scanner monitors up to 10 different channels for paging tones (two-tone sequential, single tone, and group tone). Normally, the scanner monitors each of the 10 channels in turn. However, if any tone-out channels share the same frequency, modulator, and attenuator settings, the scanner checks these channels simultaneously.

Configuring Tone Out channels

To configure Tone-Out channels:

1.Go to the Tone-Out for... menu.

2.Select Tone-Out Setup.

3.Select the Tone-Out channel (Tone-Out 1 through Tone-Out 10 ) you want to configure.

4.Select Set Frequencies and choose the frequencies for this channel

5.Select Set Tone and program Tone A and Tone B.

6.Set any of the other properties as you prefer (they aren't required).

Required

Frequencies ( Set Frequencies)

 

Tone A and Tone B ( Set Tones)

 

 

Recommended

Name ( Edit Name)

Optional

Automatic Gain Control ( Set Audio AGC)

 

Delay Time ( Set Delay Time)

 

Alert ( Set Alert)

 

 

Using Tone-Out Mode

To start a Tone-Out search:

1.Tap MENU.

2.Scroll down and select Tone-Out for...

3.Select Tone-Out Standby to start the search.

The scanner starts searching the most recently-used Tone-Out channel (and any other Tone-Out Channels that have the same frequency).

If you want to search a different channel, just turn the SELECT-VOLUME- SCROLL knob until you find the channel you want.