UBCD396XT

51.Tone A and Tone B Settings

You can configure the scanner to search for tones in several different ways, based on the values you enter for Tone A and Tone B:

Tone A

Positive number

Tone B Setting

Positive number

setting

 

 

 

Operation Monitor the

channel for two-tone pages only. The scanner opens

squelch and displays the tone information when the following occur:

1.The scanner detects a tone that matches the value you set for Tone A.

2.The tone is at least 250 ms long.

3.Within 500 ms, the scanner detects a second tone that matches the value set for Tone B.

4.The second tone is at least 100 ms long.

Tone A

Positive number

Tone B Setting

0.0 Hz

setting

 

 

 

Operation Monitor the

channel for single-

tone pages only. The scanner opens

squelch and displays the tone information when the following occur:

1.The scanner detects a tone that matches the value you set for Tone A.

2.The tone is at least 1.25 seconds long and not more than 3.75 seconds long.

Tone A

0.0 Hz

Tone B Setting

Positive number

setting

 

 

 

Operation Monitor the

channel for group

tones only. The scanner opens squelch

and displays the tone information when the following occur:

1.The scanner detects a tone that matches the value you set for Tone

B.

2.The tone is at least 3.75 seconds long.

Tone A

0.0 Hz

Tone B Setting

 

0.0 Hz

setting

 

 

 

 

Operation Monitor the

channel for two-tone pages, single-tone pages, and group

tones. This tone out search mode works as follows:

 

1.All detected tones are compared to the three criteria listed above.