Chapter 22 Mgmt Config and System Restart Menu

Click Mgmt Config > SNTP to open the following screen.

Figure 84 Mgmt Config > SNTP

The following table describes the labels in this screen.

Table 68 Mgmt Config > SNTP

LABEL

DESCRIPTION

SNTP Status

Use this to enable or disable time server for the MES-2110.

 

 

SNTP Server 1 and 2

Enter the IP address of your time server.

 

 

SNTP Request Interval

Specify how often (in hours) should the MES-2110 synchronize

 

with the time server.

 

For example, if you set the field to 2 hours, the MES-2110

 

synchronizes date/time with the time server every 2hours.

 

 

Current Time

Specify the date (in year, month and day format) and time (in

 

hour, minute and second format).

 

 

Time Zone

Select the time difference between UTC (Universal Time

 

Coordinated, formerly known as GMT, Greenwich Mean Time)

 

and your time zone.

 

 

Day Light Saving

Daylight saving is a period from late spring to early fall when

 

many countries set their clocks ahead of normal local time by

 

one hour to give more daytime light in the evening.

 

Enable this option if you use Daylight Saving Time.

 

 

Day Light Saving Start

Configure the day and time when Daylight Saving Time starts if

 

you selected Daylight Saving Time. The time is displayed in

 

the 24 hour format. Here are a couple of examples:

 

Daylight Saving Time starts in most parts of the United States

 

on the second Sunday of March. Each time zone in the United

 

States starts using Daylight Saving Time at 2 A.M. local time.

 

You’ll have to manually configure the date every year as the

 

date changes every year.

 

 

MES-2110 User’s Guide

169