Chapter 24 Troubleshooting

I cannot connect to the Web Configurator over the console port.

Ensure that your console settings are configured with the following settings:

SETTING

DEFAULT VALUE

Terminal Emulation

VT100

 

 

Baud Rate

9600

 

 

Parity

None

 

 

Number of Data Bits

8

 

 

Number of Stop Bits

1

 

 

Flow Control

None

 

 

I keep getting ‘Invalid command’ messages when trying to configure the MES- 2110 over the console port.

There are a number of different modes in the MES-2110 command line interface. In order to use certain commands, you must be in the appropriate mode. See Chapter 23 on page 179 for information on the different modes, how they work, and which commands you may use in them.

To see which commands are available to you while using the command line interface, type ? and press [ENTER].

I enabled ARP inspection on my MES-2110 but it doesn’t seem to be working.

It is recommended you enable DHCP snooping at least one day before you enable ARP inspection so that the MES-2110 has enough time to build the binding table.

My changes in the Web Configurator keep getting overwritten.

The MES-2110 allows up to five different accounts to access its Web Configurator. Make sure that you and another user are not modifying the device at the same time. Any changes you make will be overwritten when the other user saves his or her changes, and vice versa.

212

MES-2110 User’s Guide

Page 212
Image 212
ZyXEL Communications MES-2110 manual 212, My changes in the Web Configurator keep getting overwritten