Chapter 23 Command Line Interface

Table 80 Configuration Mode Commands

COMMAND

DESCRIPTION

dot1x enable

Enables 802.1x on the device.

dot1x reauth-max <1~10>

Sets the maximum number of times re-

 

authentication can be used (1~10). The default

 

is 2 times. This kind of authentication method is

 

port-based.

 

 

dot1x guest-vlan <1-4094>

Sets the VLAN ID of the guest VLAN. This must

 

be an existing VLAN.

 

 

dot1x radius-server server-ip <ip-address>

Sets the RADIUS server’s IP address.

dot1x radius-server shared-secret <string>

Sets the password for RADIUS server access.

 

string: Enter a maximum of 29 characters.

dot1x radius-server server-udp-port <1-

Sets the UDP port number of the RADIUS server.

65535>

The default is 1812.

dot1x radius-server accounting-port <1-

Sets the accounting port of the RADIUS server.

65535>

The default is 1813.

dot1x radius-server timeout <1-300>

Sets the timeout period of the RADIUS server.

 

The default is 30.

 

 

email-alarm disable

Disables the email alarm. This is the default.

email-alarm enable

Enables the email alarm.

email-alarm from <stringcr>

Sets the email alarm’s “from” field to the

 

specified string.

 

string: Enter up to 63 characters.

 

cr: Leave this blank and press the [Enter] key

 

to clear the email-alarm from setting.

 

 

email-alarm server <ip-address>

Sets the email alarm’s server to the specified IP

 

address.

 

 

email-alarm to [<id> <string>

Sets the email alarm’s “to” field.

<enabledisable>] [<id>]

id: Enter an ID number for this recipent (1~5).

 

 

If you enter just the ID and no other paramters

 

(string or enabledisable), then this

 

setting is cleared for that ID.

 

string: Enter the recipient’s email address.

 

enabledisable: Select whether to enable

 

this recipient or disable it. When disabled, no

 

alarm emails are sent to that recipient.

 

 

email-alarm type

Sets the email alarm type. When one of these

<coldstartwarmstartrj45uprj45downgigeu

events occurs and you have enabled that email

pgigedownconfchangenewroot1dtopochange

alarm type, the device sends out an alarm

1darpinspectionover> <enabledisable>

email. You must configure each event

 

individually.

 

For example: email-alarm type coldstart

 

enable. This enables it for the coldstart event.

 

If you want to also enable it for the warmstart

 

event, you must configure it separately:

 

email-alarm type warmstart enable.

188

MES-2110 User’s Guide

Page 188
Image 188
ZyXEL Communications MES-2110 manual 188