Sigma SQC-122c manual Chapter Menus

Page 53

Chapter 3

Menus

Rate Alarm Low: Sets the % deviation below rate setpoint that causes an audible alarm.

Rate Alarm High: Sets the % deviation above rate setpoint that causes an audible alarm. The tone of the high rate alarm is lower than that of the low rate alarm.

Password Enable: If Password is enabled, the Quick Start, Film and System Menus require a password. The Process Menu can be used to select a process, but a password is required to make any changes on the Process Menu.

Password: If password is enabled, this parameter sets the sequence of SoftKeys to press to enter menus. Press the desired sequence to set the password. Holding down the top and bottom switch while powering up the SQC-122c sets the password to “1111.”

System Time: Sets the SQC-122c clock to your local time. System time is battery backed up. Does not compensate for daylight savings time.

System Date: Sets the SQC-122c date to your local time. System date is battery backed up.

3-20

Image 53
Contents SQC-122c Thin Film Deposition Controller User’s Guide Safety Symbols Safety InformationReturn Policy Warranty InformationLimitation of Warranty Chapter Operation Table of Contents Chapter Quick StartChapter Menus Chapter OptionsAppendix Thin Film Process Overview Chapter Quick Start IntroductionChapter Quick Start Front Panel Chapter Quick Start Rear Panel Power Input FuseChapter Quick Start System Connections Chapter Quick Start Installation Power Chapter Quick Start Process SetupQuick Setup SelectExit to Main Edit Mode LayerChapter Quick Start Chapter Quick Start Depositing a Film This page left blank for your notes Defining a Film Chapter Operation IntroductionDefinitions POWER% POWER% Deposition Controls Menu Layer Edit Menu Chapter Operation Defining a ProcessChapter Operation Chapter Operation Sensor Setup Tooling U n d e r 1 0 0 % Chapter Operation Chapter Operation Source Setup Chapter Operation Running a Process Chapter Operation Next Menu Zero THICKNESSkA RATEA/s 824 55.3 Chapter Operation Loop Tuning Chapter Operation No Readings, or Erratic Readings from Sensors Chapter Operation TroubleshootingPoor Rate Stability Incorrect Rate or Thickness MeasurementThis page left blank for your notes Chapter Menus Introduction Chapter Menus Main Menu Default, power-up Main Screen display is shown belowNext SetupMenu Quick FilmChapter Menus Next Menu Screens Exit to Main Edit Chapter Menus Quick Setup MenuPrev Layer Next LayerChapter Menus Main Screen Prev Menu Select Edit Delete Control Knob Chapter Menus Process MenusInsert Layer Control Knob Main Screen Prev Menu Edit Cut PasteExit to Main Prev Menu Edit Control Knob POWER%Chapter Menus Main Screen Prev Menu Edit Delete Control Knob Chapter Menus Film MenusExit to Main Prev Menu Edit Exit to Main Prev Menu Edit THICKNESSkA RATEA/s Deposition Controls Menu Chapter Menus Chapter Menus Chapter Menus Chapter Menus System Parameters Menu Chapter Menus Chapter Menus Mapping Menu Chapter Menus I/O SetupInputs Explanation high input causes Relays Explanation closes whenThis page left blank for your notes Option Card Full Rack Extender InstallationChapter Options Introduction Appendix Material Parameters General Specifications Appendix SpecificationsMeasurement SourceDisplay Appendix O Connections Connector Wiring Relay PinsInput Pins Appendix Appendix Handheld Remote Controller Appendix EC Declaration of Conformity Complies with the Essential Health and Safety RequirementsDeclares that the product Uses the following standards