Sigma SQC-122c manual Tooling U n d e r 1 0 0 %

Page 22

Chapter 2

Operation

Sensor Tooling, also found in the System Params menu, adjusts for the difference in measured deposition rate between the sensor and the substrate being coated.

Substrate

S u b s t r a t e

T o o l i n g O v e r 1 0 0 %

Tooling U n d e r 1 0 0 %

In the illustration above (left), the sensor will measure less rate or thickness than is actually deposited on the substrate because of its positioning. In the right illustration, the sensor will measure high. Tooling is the ratio of the actual substrate deposition rate or thickness, to that measured by the sensor.

Let’s assume that at the end of deposition the sensor measures a thickness of 1.000 kA. But, suppose the actual substrate is deposited to 1.100 kA thickness (as determined by some other means, such as a stylus profilometer). Then the tooling for this sensor would be:

(1.100 / 1.000) x 100 = 110

A simple rule to remembers is: If the rate/thickness reading is low, then increase the tooling value. If the rate/thickness reading is high, then lower the tooling value.

Xtal Tool 1 and 2 adjust the tooling for each individual sensor. It is particularly important when using sensor averaging to balance multiple sensors so that their measurements match.

System Tooling applies to the overall Rate and Thickness measurements of all sensors. It is sometimes used to adjust for some systematic difference in the actual vs. measured readings. In general, Crystal Tooling (Xtal Tool 1 and 2) should be used instead.

2-8

Image 22
Contents SQC-122c Thin Film Deposition Controller User’s Guide Safety Information Safety SymbolsLimitation of Warranty Warranty InformationReturn Policy Chapter Menus Table of Contents Chapter Quick StartChapter Operation Chapter OptionsAppendix Chapter Quick Start Introduction Thin Film Process OverviewChapter Quick Start Front Panel Power Input Fuse Chapter Quick Start Rear PanelChapter Quick Start System Connections Chapter Quick Start Installation Quick Setup Chapter Quick Start Process SetupPower SelectChapter Quick Start Edit Mode LayerExit to Main Chapter Quick Start Depositing a Film This page left blank for your notes Definitions Chapter Operation IntroductionDefining a Film POWER% POWER% Deposition Controls Menu Chapter Operation Defining a Process Layer Edit MenuChapter Operation Chapter Operation Sensor Setup Tooling U n d e r 1 0 0 % Chapter Operation Chapter Operation Source Setup Chapter Operation Running a Process Chapter Operation Next Menu Zero THICKNESSkA RATEA/s 824 55.3 Chapter Operation Loop Tuning Chapter Operation Chapter Operation Troubleshooting No Readings, or Erratic Readings from SensorsIncorrect Rate or Thickness Measurement Poor Rate StabilityThis page left blank for your notes Chapter Menus Introduction Default, power-up Main Screen display is shown below Chapter Menus Main MenuMenu Quick SetupNext FilmChapter Menus Next Menu Screens Prev Layer Chapter Menus Quick Setup MenuExit to Main Edit Next LayerChapter Menus Chapter Menus Process Menus Main Screen Prev Menu Select Edit Delete Control KnobMain Screen Prev Menu Edit Cut Paste Insert Layer Control KnobPOWER% Exit to Main Prev Menu Edit Control KnobChapter Menus Chapter Menus Film Menus Main Screen Prev Menu Edit Delete Control KnobExit to Main Prev Menu Edit Exit to Main Prev Menu Edit THICKNESSkA RATEA/s Deposition Controls Menu Chapter Menus Chapter Menus Chapter Menus Chapter Menus System Parameters Menu Chapter Menus Chapter Menus Chapter Menus I/O Setup Mapping MenuRelays Explanation closes when Inputs Explanation high input causesThis page left blank for your notes Chapter Options Introduction Full Rack Extender InstallationOption Card Appendix Material Parameters Measurement Appendix SpecificationsGeneral Specifications SourceDisplay Input Pins Connector Wiring Relay PinsAppendix O Connections Appendix Appendix Handheld Remote Controller Declares that the product Complies with the Essential Health and Safety RequirementsAppendix EC Declaration of Conformity Uses the following standards